CF SHS 180×180×10 - Section Properties
The CF SHS 180×180×10 is a square hollow section with a mass of 50.7 kg/m, an overall depth of 180 mm and width of 180 mm and a wall thickness of 10 mm. It has a cross-sectional area of 64.6 cm², a second moment of area Iᵧ of 3020 cm⁴, a plastic modulus Wₚₗ,ᵧ of 404 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for CF SHS 180×180×10.
or pick a unit on any row

Dimension symbols for SHS Cold-formed sections. Not to scale.
Is CF SHS 180×180×10 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending30%
43.6 / 143.4 kNmShear8%
49.9 / 662.0 kNDeflection60%
5.9 / 9.7 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about CF SHS 180×180×10
Related SHS Cold-formed sizes
Compare with other sections
Side-by-side properties against the closest equivalent in each catalogue.
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.