CF SHS 180×180×6.3 - Section Properties

The CF SHS 180×180×6.3 is a square hollow section with a mass of 33.3 kg/m, an overall depth of 180 mm and width of 180 mm and a wall thickness of 6.3 mm. It has a cross-sectional area of 42.4 cm², a second moment of area Iᵧ of 2100 cm⁴, a plastic modulus Wₚₗ,ᵧ of 273 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
33.3 kg/m
Depth
180 mm
Width
180 mm
Wall thickness
6.3 mm
Area
42.4 cm²
Ask about capacity, buckling or detailing for CF SHS 180×180×6.3.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for CF SHS 180×180×6.3

Dimension symbols for SHS Cold-formed sections. Not to scale.

CF SHS 180×180×6.3 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh180
Width of sectionb180
Wall thicknesst6.3

Mass and area

Mass per metremass33.3
Cross-sectional areaA42.4

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2100
Elastic section modulus about y-axisWel,y233
Plastic section modulus about y-axisWpl,y273
Radius of gyration about y-axisiy7.03

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2100
Elastic section modulus about z-axisWel,z233
Plastic section modulus about z-axisWpl,z273
Radius of gyration about z-axisiz7.03

Torsion and warping

Torsion constant (St Venant)It3380
Section modulus for torsionWt354

Surface area

Surface area per metreSA/m0.693
Surface area per tonneSA/t20.8m²/t

Is CF SHS 180×180×6.3 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending31%
29.9 / 96.9 kNm
Shear8%
34.1 / 434.5 kN
Deflection59%
5.8 / 9.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CF SHS 180×180×6.3

CF SHS 180×180×6.3 has a mass of 33.3 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 400 kg, which is the figure to use for a steel take-off or when checking a lift.

CF SHS 180×180×6.3 has a depth of 180 mm, a width of 180 mm, a wall thickness of 6.3 mm, with a cross-sectional area of 42.4 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 273 cm³, and the elastic modulus Wel,y is 233 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 97 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,100 cm⁴, and about the minor axis Iz is 2,100 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7.03 cm about the major axis and iz is 7.03 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.03 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 3,380 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

CF SHS 160×160×8CF SHS 160×160×10CF SHS 180×180×5CF SHS 180×180×6CF SHS 180×180×8CF SHS 180×180×10CF SHS 180×180×12CF SHS 180×180×12.5

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs SHS 180×180×6.3

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Cold-formed sizes
Square Hollow Sections - Cold-formed (BS EN 10219)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…