TFC 250x80x8 - Section Properties

The TFC 250x80x8 is a tapered flange channel with a mass of 30.2 kg/m. It has a cross-sectional area of 38.5 cm², a second moment of area Iᵧ of 3630 cm⁴, an elastic modulus Wₑₗ,ᵧ of 291 cm³, tabulated by CivilAxis from Continental Steel.

Mass
30.2 kg/m
Area
38.5 cm²
Ask about capacity, buckling or detailing for TFC 250x80x8.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
Tapered Channel section profile showing the dimension symbols used for TFC 250x80x8

Dimension symbols for Tapered Channel sections. Not to scale.

TFC 250x80x8 section properties to Continental Steel.

Geometry

Web thicknesstw8
Flange thicknesstf12.5
Root fillet radiusr14
Toe radiusr27

Mass and area

Mass per metremass30.2
Cross-sectional areaA38.5

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy3630
Elastic section modulus about y-axisWel,y291
Radius of gyration about y-axisiy9.71

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz210
Elastic section modulus about z-axisWel,z35.7
Radius of gyration about z-axisiz2.34

Detailing dimensions

Centroid distance from back of leg (y)cy2.11

Common questions about TFC 250x80x8

TFC 250x80x8 has a mass of 30.2 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 362 kg, which is the figure to use for a steel take-off or when checking a lift.

The elastic section modulus about the major axis, Wel,y, is 291 cm³. Use it with M_el,Rd = Wel,y x f_y / gamma_M0 for an elastic check.

The second moment of area about the major axis, Iy, is 3,630 cm⁴, and about the minor axis Iz is 210 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 9.71 cm about the major axis and iz is 2.34 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.34 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related Tapered Channel sizes

TFC 200x80x7.5TFC 200x90x8TFC 230x80x8TFC 230x90x8.5TFC 250x90x9TFC 250x90x11TFC 280x100x9TFC 280x100x11.5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)