CivilAxisCivilAxis
☕ Support🌐 Community

TFC 280x100x9 - Section Properties

The TFC 280x100x9 is a tapered flange channel with a mass of 38.8 kg/m. It has a cross-sectional area of 49.4 cm², a second moment of area Iᵧ of 5930 cm⁴, an elastic modulus Wₑₗ,ᵧ of 423 cm³, tabulated by CivilAxis from Continental Steel.

Mass
38.8 kg/m
Area
49.4 cm²
Ask about capacity, buckling or detailing for TFC 280x100x9.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
Tapered Channel section profile showing the dimension symbols used for TFC 280x100x9

Dimension symbols for Tapered Channel sections. Not to scale.

TFC 280x100x9 section properties to Continental Steel.

Geometry

Web thicknesstw9
Flange thicknesstf13
Root fillet radiusr14
Toe radiusr27

Mass and area

Mass per metremass38.8
Cross-sectional areaA49.4

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy5930
Elastic section modulus about y-axisWel,y423
Radius of gyration about y-axisiy11

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz428
Elastic section modulus about z-axisWel,z58.2
Radius of gyration about z-axisiz2.94

Detailing dimensions

Centroid distance from back of leg (y)cy2.64

Common questions about TFC 280x100x9

TFC 280x100x9 has a mass of 38.8 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 466 kg, which is the figure to use for a steel take-off or when checking a lift.

The elastic section modulus about the major axis, Wel,y, is 423 cm³. Use it with M_el,Rd = Wel,y x f_y / gamma_M0 for an elastic check.

The second moment of area about the major axis, Iy, is 5,930 cm⁴, and about the minor axis Iz is 428 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 11 cm about the major axis and iz is 2.94 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.94 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related Tapered Channel sizes

TFC 230x90x8.5TFC 250x80x8TFC 250x90x9TFC 250x90x11TFC 280x100x11.5TFC 300x90x9TFC 300x90x10TFC 300x90x12

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)