CivilAxisCivilAxis
☕ Support🌐 Community

TFC 300x90x12 - Section Properties

The TFC 300x90x12 is a tapered flange channel with a mass of 48.6 kg/m. It has a cross-sectional area of 61.9 cm², a second moment of area Iᵧ of 7870 cm⁴, an elastic modulus Wₑₗ,ᵧ of 525 cm³, tabulated by CivilAxis from Continental Steel.

Mass
48.6 kg/m
Area
61.9 cm²
Ask about capacity, buckling or detailing for TFC 300x90x12.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
Tapered Channel section profile showing the dimension symbols used for TFC 300x90x12

Dimension symbols for Tapered Channel sections. Not to scale.

TFC 300x90x12 section properties to Continental Steel.

Geometry

Web thicknesstw12
Flange thicknesstf16
Root fillet radiusr19
Toe radiusr29.5

Mass and area

Mass per metremass48.6
Cross-sectional areaA61.9

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy7870
Elastic section modulus about y-axisWel,y525
Radius of gyration about y-axisiy11.3

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz379
Elastic section modulus about z-axisWel,z56.4
Radius of gyration about z-axisiz2.48

Detailing dimensions

Centroid distance from back of leg (y)cy2.28

Common questions about TFC 300x90x12

TFC 300x90x12 has a mass of 48.6 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 583 kg, which is the figure to use for a steel take-off or when checking a lift.

The elastic section modulus about the major axis, Wel,y, is 525 cm³. Use it with M_el,Rd = Wel,y x f_y / gamma_M0 for an elastic check.

The second moment of area about the major axis, Iy, is 7,870 cm⁴, and about the minor axis Iz is 379 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 11.3 cm about the major axis and iz is 2.48 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.48 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related Tapered Channel sizes

TFC 230x90x8.5TFC 250x80x8TFC 250x90x9TFC 250x90x11TFC 280x100x9TFC 280x100x11.5TFC 300x90x9TFC 300x90x10

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All Tapered Channel sizes
Tapered Flange Channels
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…