UB 305×102×33 - Section Properties

The UB 305×102×33 is a universal beam with a mass of 32.8 kg/m, an overall depth of 312.7 mm and width of 102.4 mm. It has a cross-sectional area of 41.8 cm², a second moment of area Iᵧ of 6500 cm⁴, a plastic modulus Wₚₗ,ᵧ of 481 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
32.8 kg/m
Depth
312.7 mm
Width
102.4 mm
Area
41.8 cm²
Ask about capacity, buckling or detailing for UB 305×102×33.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 305×102×33

Dimension symbols for UB sections. Not to scale.

UB 305×102×33 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh312.7
Width of sectionb102.4
Web thicknesstw6.6
Flange thicknesstf10.8
Root fillet radiusr7.6
Depth between filletsd275.9

Mass and area

Mass per metremass32.8
Cross-sectional areaA41.8

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy6500
Elastic section modulus about y-axisWel,y416
Plastic section modulus about y-axisWpl,y481
Radius of gyration about y-axisiy12.5

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz194
Elastic section modulus about z-axisWel,z37.9
Plastic section modulus about z-axisWpl,z60
Radius of gyration about z-axisiz2.15

Torsion and warping

Torsion constant (St Venant)It12.2
Warping constantIw0.0442

Classification and stability

Flange local-buckling ratiocf/tf3.73
Web local-buckling ratiocw/tw41.8
Buckling parameteru0.867
Torsional indexX31.6

Detailing dimensions

End clearanceC5
Notch dimension NN58
Notch dimension nn20

Surface area

Surface area per metreSA/m1.01
Surface area per tonneSA/t30.8m²/t

Is UB 305×102×33 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending30%
51.5 / 170.8 kNm
Shear7%
31.7 / 451.6 kN
Deflection61%
11.1 / 18.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 305×102×33

UB 305×102×33 has a mass of 32.8 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 394 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 305×102×33 has a depth of 312.7 mm, a width of 102.4 mm, a web thickness of 6.6 mm, a flange thickness of 10.8 mm, with a cross-sectional area of 41.8 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 481 cm³, and the elastic modulus Wel,y is 416 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 171 kNm before any stability check.

The second moment of area about the major axis, Iy, is 6,500 cm⁴, and about the minor axis Iz is 194 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 3.73 for the flange and cw/tw = 41.8 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 12.5 cm about the major axis and iz is 2.15 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.15 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 12.2 cm⁴, and the warping constant Iw is 0.0442 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 305×165×40UB 305×127×48UB 305×127×42UB 305×127×37UB 305×102×28UB 305×102×25UB 254×146×43UB 254×146×37

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 12X22vs H-300x150x5.5x8

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…