UB 305×165×40 - Section Properties
The UB 305×165×40 is a universal beam with a mass of 40.3 kg/m, an overall depth of 303.4 mm and width of 165 mm. It has a cross-sectional area of 51.3 cm², a second moment of area Iᵧ of 8500 cm⁴, a plastic modulus Wₚₗ,ᵧ of 623 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for UB 305×165×40.
or pick a unit on any row

Dimension symbols for UB sections. Not to scale.
Is UB 305×165×40 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 62% utilised, deflection governs
Bending34%
74.3 / 221.2 kNmShear12%
49.5 / 411.3 kNDeflection62%
10.4 / 16.7 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about UB 305×165×40
Related UB sizes
Compare with other sections
Side-by-side properties against the closest equivalent in each catalogue.
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.