UB 305×165×46 - Section Properties

The UB 305×165×46 is a universal beam with a mass of 46.1 kg/m, an overall depth of 306.6 mm and width of 165.7 mm. It has a cross-sectional area of 58.7 cm², a second moment of area Iᵧ of 9900 cm⁴, a plastic modulus Wₚₗ,ᵧ of 720 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
46.1 kg/m
Depth
306.6 mm
Width
165.7 mm
Area
58.7 cm²
Ask about capacity, buckling or detailing for UB 305×165×46.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 305×165×46

Dimension symbols for UB sections. Not to scale.

UB 305×165×46 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh306.6
Width of sectionb165.7
Web thicknesstw6.7
Flange thicknesstf11.8
Root fillet radiusr8.9
Depth between filletsd265.2

Mass and area

Mass per metremass46.1
Cross-sectional areaA58.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy9900
Elastic section modulus about y-axisWel,y646
Plastic section modulus about y-axisWpl,y720
Radius of gyration about y-axisiy13

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz896
Elastic section modulus about z-axisWel,z108
Plastic section modulus about z-axisWpl,z166
Radius of gyration about z-axisiz3.9

Torsion and warping

Torsion constant (St Venant)It22.2
Warping constantIw0.195

Classification and stability

Flange local-buckling ratiocf/tf5.98
Web local-buckling ratiocw/tw39.6
Buckling parameteru0.89
Torsional indexX27.1

Detailing dimensions

End clearanceC5
Notch dimension NN90
Notch dimension nn22

Surface area

Surface area per metreSA/m1.25
Surface area per tonneSA/t27.1m²/t

Is UB 305×165×46 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 58% utilised, deflection governs
Bending32%
81.0 / 255.6 kNm
Shear12%
54.0 / 460.9 kN
Deflection58%
9.7 / 16.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 305×165×46

UB 305×165×46 has a mass of 46.1 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 553 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 305×165×46 has a depth of 306.6 mm, a width of 165.7 mm, a web thickness of 6.7 mm, a flange thickness of 11.8 mm, with a cross-sectional area of 58.7 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 720 cm³, and the elastic modulus Wel,y is 646 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 256 kNm before any stability check.

The second moment of area about the major axis, Iy, is 9,900 cm⁴, and about the minor axis Iz is 896 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.98 for the flange and cw/tw = 39.6 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 13 cm about the major axis and iz is 3.9 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.9 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 22.2 cm⁴, and the warping constant Iw is 0.195 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 356×171×45UB 356×127×39UB 356×127×33UB 305×165×54UB 305×165×40UB 305×127×48UB 305×127×42UB 305×127×37

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE O 300vs W 12X30vs S 12X35vs H-300x150x7.5x12

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…