CivilAxisCivilAxis
☕ Support🌐 Community

UB 305×165×54 - Section Properties

The UB 305×165×54 is a universal beam with a mass of 54 kg/m, an overall depth of 310.4 mm and width of 166.9 mm. It has a cross-sectional area of 68.8 cm², a second moment of area Iᵧ of 11700 cm⁴, a plastic modulus Wₚₗ,ᵧ of 846 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
54 kg/m
Depth
310.4 mm
Width
166.9 mm
Area
68.8 cm²
Ask about capacity, buckling or detailing for UB 305×165×54.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 305×165×54

Dimension symbols for UB sections. Not to scale.

UB 305×165×54 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh310.4
Width of sectionb166.9
Web thicknesstw7.9
Flange thicknesstf13.7
Root fillet radiusr8.9
Depth between filletsd265.2

Mass and area

Mass per metremass54
Cross-sectional areaA68.8

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy11700
Elastic section modulus about y-axisWel,y754
Plastic section modulus about y-axisWpl,y846
Radius of gyration about y-axisiy13

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1060
Elastic section modulus about z-axisWel,z127
Plastic section modulus about z-axisWpl,z196
Radius of gyration about z-axisiz3.93

Torsion and warping

Torsion constant (St Venant)It34.8
Warping constantIw0.234

Classification and stability

Flange local-buckling ratiocf/tf5.15
Web local-buckling ratiocw/tw33.6
Buckling parameteru0.889
Torsional indexX23.6

Detailing dimensions

End clearanceC6
Notch dimension NN90
Notch dimension nn24

Surface area

Surface area per metreSA/m1.26
Surface area per tonneSA/t23.3m²/t

Is UB 305×165×54 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending34%
101.3 / 300.3 kNm
Shear12%
67.5 / 545.0 kN
Deflection62%
10.3 / 16.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 305×165×54

UB 305×165×54 has a mass of 54 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 648 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 305×165×54 has a depth of 310.4 mm, a width of 166.9 mm, a web thickness of 7.9 mm, a flange thickness of 13.7 mm, with a cross-sectional area of 68.8 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 846 cm³, and the elastic modulus Wel,y is 754 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 300 kNm before any stability check.

The second moment of area about the major axis, Iy, is 11,700 cm⁴, and about the minor axis Iz is 1,060 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.15 for the flange and cw/tw = 33.6 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 13 cm about the major axis and iz is 3.93 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.93 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 34.8 cm⁴, and the warping constant Iw is 0.234 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 356×171×51UB 356×171×45UB 356×127×39UB 356×127×33UB 305×165×46UB 305×165×40UB 305×127×48UB 305×127×42

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 12X35vs S 12X40.8vs H-300x200x8x12-55.8

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…