CivilAxisCivilAxis
☕ Support🌐 Community

UB 305×127×37 - Section Properties

The UB 305×127×37 is a universal beam with a mass of 37 kg/m, an overall depth of 304.4 mm and width of 123.4 mm. It has a cross-sectional area of 47.1 cm², a second moment of area Iᵧ of 7170 cm⁴, a plastic modulus Wₚₗ,ᵧ of 539 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
37 kg/m
Depth
304.4 mm
Width
123.4 mm
Area
47.1 cm²
Ask about capacity, buckling or detailing for UB 305×127×37.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 305×127×37

Dimension symbols for UB sections. Not to scale.

UB 305×127×37 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh304.4
Width of sectionb123.4
Web thicknesstw7.1
Flange thicknesstf10.7
Root fillet radiusr8.9
Depth between filletsd265.2

Mass and area

Mass per metremass37
Cross-sectional areaA47.1

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy7170
Elastic section modulus about y-axisWel,y471
Plastic section modulus about y-axisWpl,y539
Radius of gyration about y-axisiy12.3

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz336
Elastic section modulus about z-axisWel,z54.5
Plastic section modulus about z-axisWpl,z85.4
Radius of gyration about z-axisiz2.67

Torsion and warping

Torsion constant (St Venant)It14.8
Warping constantIw0.0725

Classification and stability

Flange local-buckling ratiocf/tf4.6
Web local-buckling ratiocw/tw37.4
Buckling parameteru0.872
Torsional indexX29.7

Detailing dimensions

End clearanceC6
Notch dimension NN70
Notch dimension nn20

Surface area

Surface area per metreSA/m1.07
Surface area per tonneSA/t28.9m²/t

Is UB 305×127×37 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending32%
60.8 / 191.3 kNm
Shear8%
40.5 / 478.7 kN
Deflection61%
10.1 / 16.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 305×127×37

UB 305×127×37 has a mass of 37 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 444 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 305×127×37 has a depth of 304.4 mm, a width of 123.4 mm, a web thickness of 7.1 mm, a flange thickness of 10.7 mm, with a cross-sectional area of 47.1 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 539 cm³, and the elastic modulus Wel,y is 471 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 191 kNm before any stability check.

The second moment of area about the major axis, Iy, is 7,170 cm⁴, and about the minor axis Iz is 336 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.6 for the flange and cw/tw = 37.4 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 12.3 cm about the major axis and iz is 2.67 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.67 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 14.8 cm⁴, and the warping constant Iw is 0.0725 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 305×165×46UB 305×165×40UB 305×127×48UB 305×127×42UB 305×102×33UB 305×102×28UB 305×102×25UB 254×146×43

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE A 300vs H-300x150x6.5x9

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…