CivilAxisCivilAxis
☕ Support🌐 Community

UC 152×152×44 - Section Properties

The UC 152×152×44 is a universal column with a mass of 44 kg/m, an overall depth of 166 mm and width of 155.9 mm. It has a cross-sectional area of 56.1 cm², a second moment of area Iᵧ of 2700 cm⁴, a plastic modulus Wₚₗ,ᵧ of 372 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
44 kg/m
Depth
166 mm
Width
155.9 mm
Area
56.1 cm²
Ask about capacity, buckling or detailing for UC 152×152×44.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 152×152×44

Dimension symbols for UC sections. Not to scale.

UC 152×152×44 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh166
Width of sectionb155.9
Web thicknesstw9.5
Flange thicknesstf13.6
Root fillet radiusr7.6
Depth between filletsd123.6

Mass and area

Mass per metremass44
Cross-sectional areaA56.1

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2700
Elastic section modulus about y-axisWel,y326
Plastic section modulus about y-axisWpl,y372
Radius of gyration about y-axisiy6.94

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz860
Elastic section modulus about z-axisWel,z110
Plastic section modulus about z-axisWpl,z169
Radius of gyration about z-axisiz3.92

Torsion and warping

Torsion constant (St Venant)It31.7
Warping constantIw0.05

Classification and stability

Flange local-buckling ratiocf/tf4.82
Web local-buckling ratiocw/tw13
Buckling parameteru0.848
Torsional indexX11.5

Detailing dimensions

End clearanceC7
Notch dimension NN84
Notch dimension nn22

Surface area

Surface area per metreSA/m0.924
Surface area per tonneSA/t21m²/t

Is UC 152×152×44 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending30%
39.0 / 132.1 kNm
Shear13%
44.6 / 349.5 kN
Deflection60%
5.9 / 9.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 152×152×44

UC 152×152×44 has a mass of 44 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 528 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 152×152×44 has a depth of 166 mm, a width of 155.9 mm, a web thickness of 9.5 mm, a flange thickness of 13.6 mm, with a cross-sectional area of 56.1 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 372 cm³, and the elastic modulus Wel,y is 326 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 132 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,700 cm⁴, and about the minor axis Iz is 860 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.82 for the flange and cw/tw = 13 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 6.94 cm about the major axis and iz is 3.92 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.92 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 31.7 cm⁴, and the warping constant Iw is 0.05 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 203×203×71UC 203×203×60UC 203×203×52UC 203×203×46UC 152×152×51UC 152×152×37UC 152×152×30UC 152×152×23

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs H-175x175x7.5x11-40.4

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…