CivilAxisCivilAxis
☕ Support🌐 Community

UC 203×203×71 - Section Properties

The UC 203×203×71 is a universal column with a mass of 71 kg/m, an overall depth of 215.8 mm and width of 206.4 mm. It has a cross-sectional area of 90.4 cm², a second moment of area Iᵧ of 7620 cm⁴, a plastic modulus Wₚₗ,ᵧ of 799 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
71 kg/m
Depth
215.8 mm
Width
206.4 mm
Area
90.4 cm²
Ask about capacity, buckling or detailing for UC 203×203×71.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 203×203×71

Dimension symbols for UC sections. Not to scale.

UC 203×203×71 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh215.8
Width of sectionb206.4
Web thicknesstw10
Flange thicknesstf17.3
Root fillet radiusr10.2
Depth between filletsd160.8

Mass and area

Mass per metremass71
Cross-sectional areaA90.4

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy7620
Elastic section modulus about y-axisWel,y706
Plastic section modulus about y-axisWpl,y799
Radius of gyration about y-axisiy9.18

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2540
Elastic section modulus about z-axisWel,z246
Plastic section modulus about z-axisWpl,z374
Radius of gyration about z-axisiz5.3

Torsion and warping

Torsion constant (St Venant)It80.2
Warping constantIw0.25

Classification and stability

Flange local-buckling ratiocf/tf5.09
Web local-buckling ratiocw/tw16.1
Buckling parameteru0.853
Torsional indexX11.9

Detailing dimensions

End clearanceC7
Notch dimension NN110
Notch dimension nn28

Surface area

Surface area per metreSA/m1.22
Surface area per tonneSA/t17.2m²/t

Is UC 203×203×71 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending29%
83.5 / 283.6 kNm
Shear15%
74.3 / 496.9 kN
Deflection59%
7.3 / 12.5 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 203×203×71

UC 203×203×71 has a mass of 71 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 852 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 203×203×71 has a depth of 215.8 mm, a width of 206.4 mm, a web thickness of 10 mm, a flange thickness of 17.3 mm, with a cross-sectional area of 90.4 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 799 cm³, and the elastic modulus Wel,y is 706 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 284 kNm before any stability check.

The second moment of area about the major axis, Iy, is 7,620 cm⁴, and about the minor axis Iz is 2,540 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.09 for the flange and cw/tw = 16.1 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 9.18 cm about the major axis and iz is 5.3 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5.3 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 80.2 cm⁴, and the warping constant Iw is 0.25 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 203×203×127UC 203×203×113UC 203×203×100UC 203×203×86UC 203×203×60UC 203×203×52UC 203×203×46UC 152×152×51

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs HE 220 Bvs W 8X48

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…