CivilAxisCivilAxis
☕ Support🌐 Community

UC 203×203×46 - Section Properties

The UC 203×203×46 is a universal column with a mass of 46.1 kg/m, an overall depth of 203.2 mm and width of 203.6 mm. It has a cross-sectional area of 58.7 cm², a second moment of area Iᵧ of 4570 cm⁴, a plastic modulus Wₚₗ,ᵧ of 497 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
46.1 kg/m
Depth
203.2 mm
Width
203.6 mm
Area
58.7 cm²
Ask about capacity, buckling or detailing for UC 203×203×46.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 203×203×46

Dimension symbols for UC sections. Not to scale.

UC 203×203×46 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh203.2
Width of sectionb203.6
Web thicknesstw7.2
Flange thicknesstf11
Root fillet radiusr10.2
Depth between filletsd160.8

Mass and area

Mass per metremass46.1
Cross-sectional areaA58.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy4570
Elastic section modulus about y-axisWel,y450
Plastic section modulus about y-axisWpl,y497
Radius of gyration about y-axisiy8.82

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1550
Elastic section modulus about z-axisWel,z152
Plastic section modulus about z-axisWpl,z231
Radius of gyration about z-axisiz5.13

Torsion and warping

Torsion constant (St Venant)It22.2
Warping constantIw0.143

Classification and stability

Flange local-buckling ratiocf/tf8
Web local-buckling ratiocw/tw22.3
Buckling parameteru0.847
Torsional indexX17.7

Detailing dimensions

End clearanceC6
Notch dimension NN110
Notch dimension nn22

Surface area

Surface area per metreSA/m1.19
Surface area per tonneSA/t25.8m²/t

Is UC 203×203×46 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending32%
57.0 / 176.4 kNm
Shear16%
57.0 / 347.3 kN
Deflection59%
6.6 / 11.1 mm

Class 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 203×203×46

UC 203×203×46 has a mass of 46.1 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 553 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 203×203×46 has a depth of 203.2 mm, a width of 203.6 mm, a web thickness of 7.2 mm, a flange thickness of 11 mm, with a cross-sectional area of 58.7 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 497 cm³, and the elastic modulus Wel,y is 450 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 176 kNm before any stability check.

The second moment of area about the major axis, Iy, is 4,570 cm⁴, and about the minor axis Iz is 1,550 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 8 for the flange and cw/tw = 22.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 8.82 cm about the major axis and iz is 5.13 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5.13 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 22.2 cm⁴, and the warping constant Iw is 0.143 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 203×203×86UC 203×203×71UC 203×203×60UC 203×203×52UC 152×152×51UC 152×152×44UC 152×152×37UC 152×152×30

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 8X31

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…