UC 203×203×86 - Section Properties

The UC 203×203×86 is a universal column with a mass of 86.1 kg/m, an overall depth of 222.2 mm and width of 209.1 mm. It has a cross-sectional area of 110 cm², a second moment of area Iᵧ of 9450 cm⁴, a plastic modulus Wₚₗ,ᵧ of 977 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
86.1 kg/m
Depth
222.2 mm
Width
209.1 mm
Area
110 cm²
Ask about capacity, buckling or detailing for UC 203×203×86.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 203×203×86

Dimension symbols for UC sections. Not to scale.

UC 203×203×86 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh222.2
Width of sectionb209.1
Web thicknesstw12.7
Flange thicknesstf20.5
Root fillet radiusr10.2
Depth between filletsd160.8

Mass and area

Mass per metremass86.1
Cross-sectional areaA110

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy9450
Elastic section modulus about y-axisWel,y850
Plastic section modulus about y-axisWpl,y977
Radius of gyration about y-axisiy9.28

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3130
Elastic section modulus about z-axisWel,z299
Plastic section modulus about z-axisWpl,z456
Radius of gyration about z-axisiz5.34

Torsion and warping

Torsion constant (St Venant)It137
Warping constantIw0.318

Classification and stability

Flange local-buckling ratiocf/tf4.29
Web local-buckling ratiocw/tw12.7
Buckling parameteru0.85
Torsional indexX10.2

Detailing dimensions

End clearanceC8
Notch dimension NN110
Notch dimension nn32

Surface area

Surface area per metreSA/m1.24
Surface area per tonneSA/t14.4m²/t

Is UC 203×203×86 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending31%
106.3 / 346.8 kNm
Shear15%
94.5 / 636.5 kN
Deflection60%
7.5 / 12.5 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 203×203×86

UC 203×203×86 has a mass of 86.1 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1033 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 203×203×86 has a depth of 222.2 mm, a width of 209.1 mm, a web thickness of 12.7 mm, a flange thickness of 20.5 mm, with a cross-sectional area of 110 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 977 cm³, and the elastic modulus Wel,y is 850 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 347 kNm before any stability check.

The second moment of area about the major axis, Iy, is 9,450 cm⁴, and about the minor axis Iz is 3,130 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.29 for the flange and cw/tw = 12.7 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 9.28 cm about the major axis and iz is 5.34 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5.34 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 137 cm⁴, and the warping constant Iw is 0.318 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 254×254×73UC 203×203×127UC 203×203×113UC 203×203×100UC 203×203×71UC 203×203×60UC 203×203×52UC 203×203×46

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 8X58

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…