CivilAxisCivilAxis
☕ Support🌐 Community

UC 254×254×73 - Section Properties

The UC 254×254×73 is a universal column with a mass of 73.1 kg/m, an overall depth of 254.1 mm and width of 254.6 mm. It has a cross-sectional area of 93.1 cm², a second moment of area Iᵧ of 11400 cm⁴, a plastic modulus Wₚₗ,ᵧ of 992 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
73.1 kg/m
Depth
254.1 mm
Width
254.6 mm
Area
93.1 cm²
Ask about capacity, buckling or detailing for UC 254×254×73.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 254×254×73

Dimension symbols for UC sections. Not to scale.

UC 254×254×73 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh254.1
Width of sectionb254.6
Web thicknesstw8.6
Flange thicknesstf14.2
Root fillet radiusr12.7
Depth between filletsd200.3

Mass and area

Mass per metremass73.1
Cross-sectional areaA93.1

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy11400
Elastic section modulus about y-axisWel,y898
Plastic section modulus about y-axisWpl,y992
Radius of gyration about y-axisiy11.1

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3910
Elastic section modulus about z-axisWel,z307
Plastic section modulus about z-axisWpl,z465
Radius of gyration about z-axisiz6.48

Torsion and warping

Torsion constant (St Venant)It57.6
Warping constantIw0.562

Classification and stability

Flange local-buckling ratiocf/tf7.77
Web local-buckling ratiocw/tw23.3
Buckling parameteru0.849
Torsional indexX17.24

Detailing dimensions

End clearanceC6
Notch dimension NN134
Notch dimension nn28

Surface area

Surface area per metreSA/m1.49
Surface area per tonneSA/t20.4m²/t

Is UC 254×254×73 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending33%
117.2 / 352.2 kNm
Shear18%
93.8 / 525.1 kN
Deflection61%
8.5 / 13.9 mm

Class 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 254×254×73

UC 254×254×73 has a mass of 73.1 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 877 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 254×254×73 has a depth of 254.1 mm, a width of 254.6 mm, a web thickness of 8.6 mm, a flange thickness of 14.2 mm, with a cross-sectional area of 93.1 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 992 cm³, and the elastic modulus Wel,y is 898 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 352 kNm before any stability check.

The second moment of area about the major axis, Iy, is 11,400 cm⁴, and about the minor axis Iz is 3,910 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.77 for the flange and cw/tw = 23.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 11.1 cm about the major axis and iz is 6.48 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.48 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 57.6 cm⁴, and the warping constant Iw is 0.562 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 254×254×167UC 254×254×132UC 254×254×107UC 254×254×89UC 203×203×127UC 203×203×113UC 203×203×100UC 203×203×86

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 10X49vs H-250x250x9x14-72.4

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…