UC 254×254×167 - Section Properties
The UC 254×254×167 is a universal column with a mass of 167.1 kg/m, an overall depth of 289.1 mm and width of 265.2 mm. It has a cross-sectional area of 213 cm², a second moment of area Iᵧ of 30000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2420 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for UC 254×254×167.
or pick a unit on any row

Dimension symbols for UC sections. Not to scale.
Is UC 254×254×167 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 59% utilised, deflection governs
Bending29%
249.8 / 859.1 kNmShear14%
166.5 / 1209.3 kNDeflection59%
9.9 / 16.7 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about UC 254×254×167
Related UC sizes
Compare with other sections
Side-by-side properties against the closest equivalent in each catalogue.
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.