CivilAxisCivilAxis
☕ Support🌐 Community

UC 305×305×97 - Section Properties

The UC 305×305×97 is a universal column with a mass of 96.9 kg/m, an overall depth of 307.9 mm and width of 305.3 mm. It has a cross-sectional area of 123 cm², a second moment of area Iᵧ of 22200 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1590 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
96.9 kg/m
Depth
307.9 mm
Width
305.3 mm
Area
123 cm²
Ask about capacity, buckling or detailing for UC 305×305×97.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 305×305×97

Dimension symbols for UC sections. Not to scale.

UC 305×305×97 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh307.9
Width of sectionb305.3
Web thicknesstw9.9
Flange thicknesstf15.4
Root fillet radiusr15.2
Depth between filletsd246.7

Mass and area

Mass per metremass96.9
Cross-sectional areaA123

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy22200
Elastic section modulus about y-axisWel,y1450
Plastic section modulus about y-axisWpl,y1590
Radius of gyration about y-axisiy13.4

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz7310
Elastic section modulus about z-axisWel,z479
Plastic section modulus about z-axisWpl,z726
Radius of gyration about z-axisiz7.69

Torsion and warping

Torsion constant (St Venant)It91.2
Warping constantIw1.56

Classification and stability

Flange local-buckling ratiocf/tf8.6
Web local-buckling ratiocw/tw24.9
Buckling parameteru0.85
Torsional indexX19.19

Detailing dimensions

End clearanceC7
Notch dimension NN158
Notch dimension nn32

Surface area

Surface area per metreSA/m1.79
Surface area per tonneSA/t18.5m²/t

Is UC 305×305×97 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending37%
189.0 / 514.8 kNm
Shear17%
126.0 / 720.9 kN
Deflection61%
10.1 / 16.7 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 305×305×97

UC 305×305×97 has a mass of 96.9 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1163 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 305×305×97 has a depth of 307.9 mm, a width of 305.3 mm, a web thickness of 9.9 mm, a flange thickness of 15.4 mm, with a cross-sectional area of 123 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,590 cm³, and the elastic modulus Wel,y is 1,450 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 564 kNm before any stability check.

The second moment of area about the major axis, Iy, is 22,200 cm⁴, and about the minor axis Iz is 7,310 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 8.6 for the flange and cw/tw = 24.9 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 13.4 cm about the major axis and iz is 7.69 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.69 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 91.2 cm⁴, and the warping constant Iw is 1.56 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 305×305×198UC 305×305×158UC 305×305×137UC 305×305×118UC 254×254×167UC 254×254×132UC 254×254×107UC 254×254×89

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs HE 320 Avs W 12X65vs H-300x300x15x15

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam