UC 254×254×132 - Section Properties

The UC 254×254×132 is a universal column with a mass of 132 kg/m, an overall depth of 276.3 mm and width of 261.3 mm. It has a cross-sectional area of 168 cm², a second moment of area Iᵧ of 22500 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1870 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
132 kg/m
Depth
276.3 mm
Width
261.3 mm
Area
168 cm²
Ask about capacity, buckling or detailing for UC 254×254×132.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 254×254×132

Dimension symbols for UC sections. Not to scale.

UC 254×254×132 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh276.3
Width of sectionb261.3
Web thicknesstw15.3
Flange thicknesstf25.3
Root fillet radiusr12.7
Depth between filletsd200.3

Mass and area

Mass per metremass132
Cross-sectional areaA168

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy22500
Elastic section modulus about y-axisWel,y1630
Plastic section modulus about y-axisWpl,y1870
Radius of gyration about y-axisiy11.6

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz7530
Elastic section modulus about z-axisWel,z576
Plastic section modulus about z-axisWpl,z878
Radius of gyration about z-axisiz6.69

Torsion and warping

Torsion constant (St Venant)It319
Warping constantIw1.19

Classification and stability

Flange local-buckling ratiocf/tf4.36
Web local-buckling ratiocw/tw13.1
Buckling parameteru0.85
Torsional indexX10.32

Detailing dimensions

End clearanceC10
Notch dimension NN134
Notch dimension nn38

Surface area

Surface area per metreSA/m1.55
Surface area per tonneSA/t11.7m²/t

Is UC 254×254×132 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending31%
204.2 / 663.9 kNm
Shear16%
148.5 / 944.4 kN
Deflection59%
9.1 / 15.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 254×254×132

UC 254×254×132 has a mass of 132 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1584 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 254×254×132 has a depth of 276.3 mm, a width of 261.3 mm, a web thickness of 15.3 mm, a flange thickness of 25.3 mm, with a cross-sectional area of 168 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,870 cm³, and the elastic modulus Wel,y is 1,630 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 664 kNm before any stability check.

The second moment of area about the major axis, Iy, is 22,500 cm⁴, and about the minor axis Iz is 7,530 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.36 for the flange and cw/tw = 13.1 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 11.6 cm about the major axis and iz is 6.69 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.69 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 319 cm⁴, and the warping constant Iw is 1.19 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 305×305×137UC 305×305×118UC 305×305×97UC 254×254×167UC 254×254×107UC 254×254×89UC 254×254×73UC 203×203×127

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs HE 260 Cvs W 10X88vs HE 300 B

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…