CivilAxisCivilAxis
☕ Support🌐 Community

UC 305×305×198 - Section Properties

The UC 305×305×198 is a universal column with a mass of 198.1 kg/m, an overall depth of 339.9 mm and width of 314.5 mm. It has a cross-sectional area of 252 cm², a second moment of area Iᵧ of 50900 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3440 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
198.1 kg/m
Depth
339.9 mm
Width
314.5 mm
Area
252 cm²
Ask about capacity, buckling or detailing for UC 305×305×198.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 305×305×198

Dimension symbols for UC sections. Not to scale.

UC 305×305×198 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh339.9
Width of sectionb314.5
Web thicknesstw19.1
Flange thicknesstf31.4
Root fillet radiusr15.2
Depth between filletsd246.7

Mass and area

Mass per metremass198.1
Cross-sectional areaA252

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy50900
Elastic section modulus about y-axisWel,y3000
Plastic section modulus about y-axisWpl,y3440
Radius of gyration about y-axisiy14.2

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz16300
Elastic section modulus about z-axisWel,z1040
Plastic section modulus about z-axisWpl,z1580
Radius of gyration about z-axisiz8.04

Torsion and warping

Torsion constant (St Venant)It734
Warping constantIw3.88

Classification and stability

Flange local-buckling ratiocf/tf4.22
Web local-buckling ratiocw/tw12.9
Buckling parameteru0.854
Torsional indexX10.23

Detailing dimensions

End clearanceC12
Notch dimension NN158
Notch dimension nn48

Surface area

Surface area per metreSA/m1.87
Surface area per tonneSA/t9.44m²/t

Is UC 305×305×198 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending30%
367.5 / 1221.2 kNm
Shear15%
210.0 / 1435.5 kN
Deflection60%
11.7 / 19.4 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 305×305×198

UC 305×305×198 has a mass of 198.1 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 2377 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 305×305×198 has a depth of 339.9 mm, a width of 314.5 mm, a web thickness of 19.1 mm, a flange thickness of 31.4 mm, with a cross-sectional area of 252 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 3,440 cm³, and the elastic modulus Wel,y is 3,000 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1221 kNm before any stability check.

The second moment of area about the major axis, Iy, is 50,900 cm⁴, and about the minor axis Iz is 16,300 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.22 for the flange and cw/tw = 12.9 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 14.2 cm about the major axis and iz is 8.04 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 8.04 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 734 cm⁴, and the warping constant Iw is 3.88 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 356×368×153UC 356×368×129UC 305×305×283UC 305×305×240UC 305×305×158UC 305×305×137UC 305×305×118UC 305×305×97

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs HE 320 Cvs W 12X136vs H-350x350x16x25

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.