CivilAxisCivilAxis
☕ Support🌐 Community

UC 356×368×129 - Section Properties

The UC 356×368×129 is a universal column with a mass of 129 kg/m, an overall depth of 355.6 mm and width of 368.6 mm. It has a cross-sectional area of 164 cm², a second moment of area Iᵧ of 40200 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2480 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
129 kg/m
Depth
355.6 mm
Width
368.6 mm
Area
164 cm²
Ask about capacity, buckling or detailing for UC 356×368×129.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 356×368×129

Dimension symbols for UC sections. Not to scale.

UC 356×368×129 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh355.6
Width of sectionb368.6
Web thicknesstw10.4
Flange thicknesstf17.5
Root fillet radiusr15.2
Depth between filletsd290.2

Mass and area

Mass per metremass129
Cross-sectional areaA164

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy40200
Elastic section modulus about y-axisWel,y2260
Plastic section modulus about y-axisWpl,y2480
Radius of gyration about y-axisiy15.6

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz14600
Elastic section modulus about z-axisWel,z793
Plastic section modulus about z-axisWpl,z1200
Radius of gyration about z-axisiz9.43

Torsion and warping

Torsion constant (St Venant)It153
Warping constantIw4.18

Classification and stability

Flange local-buckling ratiocf/tf9.4
Web local-buckling ratiocw/tw27.9
Buckling parameteru0.844
Torsional indexX19.81

Detailing dimensions

End clearanceC7
Notch dimension NN190
Notch dimension nn34

Surface area

Surface area per metreSA/m2.14
Surface area per tonneSA/t16.6m²/t

Is UC 356×368×129 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending37%
294.0 / 802.3 kNm
Shear19%
168.0 / 863.5 kN
Deflection61%
11.9 / 19.4 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 356×368×129

UC 356×368×129 has a mass of 129 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1548 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 356×368×129 has a depth of 355.6 mm, a width of 368.6 mm, a web thickness of 10.4 mm, a flange thickness of 17.5 mm, with a cross-sectional area of 164 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 2,480 cm³, and the elastic modulus Wel,y is 2,260 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 880 kNm before any stability check.

The second moment of area about the major axis, Iy, is 40,200 cm⁴, and about the minor axis Iz is 14,600 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 9.4 for the flange and cw/tw = 27.9 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 15.6 cm about the major axis and iz is 9.43 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 9.43 cm a 0.9 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 153 cm⁴, and the warping constant Iw is 4.18 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 356×406×235UC 356×368×202UC 356×368×177UC 356×368×153UC 305×305×283UC 305×305×240UC 305×305×198UC 305×305×158

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs HE 340 Bvs W 14X90vs HP 14X89vs H-350x350x12x19-135

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…