The UC 356×368×177 is a universal column with a mass of 177 kg/m, an overall depth of 368.2 mm and width of 372.6 mm. It has a cross-sectional area of 226 cm², a second moment of area Iᵧ of 57100 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3460 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
177 kg/m
Depth
368.2 mm
Width
372.6 mm
Area
226 cm²
Ask about capacity, buckling or detailing for UC 356×368×177.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 356×368×177

Dimension symbols for UC sections. Not to scale.

UC 356×368×177 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh368.2
Width of sectionb372.6
Web thicknesstw14.4
Flange thicknesstf23.8
Root fillet radiusr15.2
Depth between filletsd290.2

Mass and area

Mass per metremass177
Cross-sectional areaA226

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy57100
Elastic section modulus about y-axisWel,y3100
Plastic section modulus about y-axisWpl,y3460
Radius of gyration about y-axisiy15.9

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz20500
Elastic section modulus about z-axisWel,z1100
Plastic section modulus about z-axisWpl,z1670
Radius of gyration about z-axisiz9.54

Torsion and warping

Torsion constant (St Venant)It381
Warping constantIw6.09

Classification and stability

Flange local-buckling ratiocf/tf6.89
Web local-buckling ratiocw/tw20.2
Buckling parameteru0.844
Torsional indexX15

Detailing dimensions

End clearanceC9
Notch dimension NN190
Notch dimension nn40

Surface area

Surface area per metreSA/m2.17
Surface area per tonneSA/t12.3m²/t

Is UC 356×368×177 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending31%
379.7 / 1228.3 kNm
Shear17%
202.5 / 1215.5 kN
Deflection59%
12.4 / 20.8 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 356×368×177

UC 356×368×177 has a mass of 177 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 2124 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 356×368×177 has a depth of 368.2 mm, a width of 372.6 mm, a web thickness of 14.4 mm, a flange thickness of 23.8 mm, with a cross-sectional area of 226 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 3,460 cm³, and the elastic modulus Wel,y is 3,100 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1228 kNm before any stability check.

The second moment of area about the major axis, Iy, is 57,100 cm⁴, and about the minor axis Iz is 20,500 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 6.89 for the flange and cw/tw = 20.2 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 15.9 cm about the major axis and iz is 9.54 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 9.54 cm a 1.0 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 381 cm⁴, and the warping constant Iw is 6.09 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 356×406×340UC 356×406×287UC 356×406×235UC 356×368×202UC 356×368×153UC 356×368×129UC 305×305×283UC 305×305×240

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 14X120vs H-350x350x16x25

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…