CivilAxisCivilAxis
☕ Support🌐 Community

UC 305×305×240 - Section Properties

The UC 305×305×240 is a universal column with a mass of 240 kg/m, an overall depth of 352.5 mm and width of 318.4 mm. It has a cross-sectional area of 306 cm², a second moment of area Iᵧ of 64200 cm⁴, a plastic modulus Wₚₗ,ᵧ of 4250 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
240 kg/m
Depth
352.5 mm
Width
318.4 mm
Area
306 cm²
Ask about capacity, buckling or detailing for UC 305×305×240.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 305×305×240

Dimension symbols for UC sections. Not to scale.

UC 305×305×240 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh352.5
Width of sectionb318.4
Web thicknesstw23
Flange thicknesstf37.7
Root fillet radiusr15.2
Depth between filletsd246.7

Mass and area

Mass per metremass240
Cross-sectional areaA306

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy64200
Elastic section modulus about y-axisWel,y3640
Plastic section modulus about y-axisWpl,y4250
Radius of gyration about y-axisiy14.5

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz20300
Elastic section modulus about z-axisWel,z1280
Plastic section modulus about z-axisWpl,z1950
Radius of gyration about z-axisiz8.15

Torsion and warping

Torsion constant (St Venant)It1270
Warping constantIw5.03

Classification and stability

Flange local-buckling ratiocf/tf3.51
Web local-buckling ratiocw/tw10.7
Buckling parameteru0.854
Torsional indexX8.73

Detailing dimensions

End clearanceC14
Notch dimension NN158
Notch dimension nn54

Surface area

Surface area per metreSA/m1.91
Surface area per tonneSA/t7.96m²/t

Is UC 305×305×240 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending30%
459.4 / 1508.8 kNm
Shear15%
262.5 / 1763.8 kN
Deflection60%
11.6 / 19.4 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 305×305×240

UC 305×305×240 has a mass of 240 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 2880 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 305×305×240 has a depth of 352.5 mm, a width of 318.4 mm, a web thickness of 23 mm, a flange thickness of 37.7 mm, with a cross-sectional area of 306 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 4,250 cm³, and the elastic modulus Wel,y is 3,640 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1509 kNm before any stability check.

The second moment of area about the major axis, Iy, is 64,200 cm⁴, and about the minor axis Iz is 20,300 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 3.51 for the flange and cw/tw = 10.7 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 14.5 cm about the major axis and iz is 8.15 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 8.15 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 1,270 cm⁴, and the warping constant Iw is 5.03 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 356×368×177UC 356×368×153UC 356×368×129UC 305×305×283UC 305×305×198UC 305×305×158UC 305×305×137UC 305×305×118

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs HE 320 Mvs W 14X145

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…