CivilAxisCivilAxis
☕ Support🌐 Community

UC 305×305×283 - Section Properties

The UC 305×305×283 is a universal column with a mass of 282.9 kg/m, an overall depth of 365.3 mm and width of 322.2 mm. It has a cross-sectional area of 360 cm², a second moment of area Iᵧ of 78900 cm⁴, a plastic modulus Wₚₗ,ᵧ of 5110 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
282.9 kg/m
Depth
365.3 mm
Width
322.2 mm
Area
360 cm²
Ask about capacity, buckling or detailing for UC 305×305×283.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 305×305×283

Dimension symbols for UC sections. Not to scale.

UC 305×305×283 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh365.3
Width of sectionb322.2
Web thicknesstw26.8
Flange thicknesstf44.1
Root fillet radiusr15.2
Depth between filletsd246.7

Mass and area

Mass per metremass282.9
Cross-sectional areaA360

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy78900
Elastic section modulus about y-axisWel,y4320
Plastic section modulus about y-axisWpl,y5110
Radius of gyration about y-axisiy14.8

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz24600
Elastic section modulus about z-axisWel,z1530
Plastic section modulus about z-axisWpl,z2340
Radius of gyration about z-axisiz8.27

Torsion and warping

Torsion constant (St Venant)It2030
Warping constantIw6.35

Classification and stability

Flange local-buckling ratiocf/tf3
Web local-buckling ratiocw/tw9.21
Buckling parameteru0.855
Torsional indexX7.64

Detailing dimensions

End clearanceC15
Notch dimension NN158
Notch dimension nn60

Surface area

Surface area per metreSA/m1.94
Surface area per tonneSA/t6.86m²/t

Is UC 305×305×283 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending29%
527.3 / 1814.0 kNm
Shear14%
281.3 / 2071.0 kN
Deflection60%
12.4 / 20.8 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 305×305×283

UC 305×305×283 has a mass of 282.9 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 3395 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 305×305×283 has a depth of 365.3 mm, a width of 322.2 mm, a web thickness of 26.8 mm, a flange thickness of 44.1 mm, with a cross-sectional area of 360 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 5,110 cm³, and the elastic modulus Wel,y is 4,320 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1814 kNm before any stability check.

The second moment of area about the major axis, Iy, is 78,900 cm⁴, and about the minor axis Iz is 24,600 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 3 for the flange and cw/tw = 9.21 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 14.8 cm about the major axis and iz is 8.27 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 8.27 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 2,030 cm⁴, and the warping constant Iw is 6.35 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 356×368×202UC 356×368×177UC 356×368×153UC 356×368×129UC 305×305×240UC 305×305×198UC 305×305×158UC 305×305×137

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 12X190vs W 14X176

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…