UC 356×406×340 - Section Properties

The UC 356×406×340 is a universal column with a mass of 339.9 kg/m, an overall depth of 406.4 mm and width of 403 mm. It has a cross-sectional area of 433 cm², a second moment of area Iᵧ of 123000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 7000 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
339.9 kg/m
Depth
406.4 mm
Width
403 mm
Area
433 cm²
Ask about capacity, buckling or detailing for UC 356×406×340.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 356×406×340

Dimension symbols for UC sections. Not to scale.

UC 356×406×340 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh406.4
Width of sectionb403
Web thicknesstw26.6
Flange thicknesstf42.9
Root fillet radiusr15.2
Depth between filletsd290.2

Mass and area

Mass per metremass339.9
Cross-sectional areaA433

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy123000
Elastic section modulus about y-axisWel,y6030
Plastic section modulus about y-axisWpl,y7000
Radius of gyration about y-axisiy16.8

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz46900
Elastic section modulus about z-axisWel,z2330
Plastic section modulus about z-axisWpl,z3540
Radius of gyration about z-axisiz10.4

Torsion and warping

Torsion constant (St Venant)It2340
Warping constantIw15.5

Classification and stability

Flange local-buckling ratiocf/tf4.03
Web local-buckling ratiocw/tw10.9
Buckling parameteru0.836
Torsional indexX8.84

Detailing dimensions

End clearanceC15
Notch dimension NN200
Notch dimension nn60

Surface area

Surface area per metreSA/m2.35
Surface area per tonneSA/t6.91m²/t

Is UC 356×406×340 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending31%
780.0 / 2485.0 kNm
Shear17%
390.0 / 2289.0 kN
Deflection60%
13.4 / 22.2 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 356×406×340

UC 356×406×340 has a mass of 339.9 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 4079 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 356×406×340 has a depth of 406.4 mm, a width of 403 mm, a web thickness of 26.6 mm, a flange thickness of 42.9 mm, with a cross-sectional area of 433 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 7,000 cm³, and the elastic modulus Wel,y is 6,030 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 2485 kNm before any stability check.

The second moment of area about the major axis, Iy, is 123,000 cm⁴, and about the minor axis Iz is 46,900 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.03 for the flange and cw/tw = 10.9 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 16.8 cm about the major axis and iz is 10.4 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 10.4 cm a 1.0 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 2,340 cm⁴, and the warping constant Iw is 15.5 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 356×406×634UC 356×406×551UC 356×406×467UC 356×406×393UC 356×406×287UC 356×406×235UC 356×368×202UC 356×368×177

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 14X233vs W 12X252

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…