UC 356×406×551 - Section Properties

The UC 356×406×551 is a universal column with a mass of 551 kg/m, an overall depth of 455.6 mm and width of 418.5 mm. It has a cross-sectional area of 702 cm², a second moment of area Iᵧ of 227000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 12100 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
551 kg/m
Depth
455.6 mm
Width
418.5 mm
Area
702 cm²
Ask about capacity, buckling or detailing for UC 356×406×551.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 356×406×551

Dimension symbols for UC sections. Not to scale.

UC 356×406×551 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh455.6
Width of sectionb418.5
Web thicknesstw42.1
Flange thicknesstf67.5
Root fillet radiusr15.2
Depth between filletsd290.2

Mass and area

Mass per metremass551
Cross-sectional areaA702

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy227000
Elastic section modulus about y-axisWel,y9960
Plastic section modulus about y-axisWpl,y12100
Radius of gyration about y-axisiy18

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz82700
Elastic section modulus about z-axisWel,z3950
Plastic section modulus about z-axisWpl,z6060
Radius of gyration about z-axisiz10.9

Torsion and warping

Torsion constant (St Venant)It9240
Warping constantIw31.1

Classification and stability

Flange local-buckling ratiocf/tf2.56
Web local-buckling ratiocw/tw6.89
Buckling parameteru0.841
Torsional indexX6.05

Detailing dimensions

End clearanceC23
Notch dimension NN200
Notch dimension nn84

Surface area

Surface area per metreSA/m2.47
Surface area per tonneSA/t4.48m²/t

Is UC 356×406×551 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending30%
1275.8 / 4295.5 kNm
Shear15%
567.0 / 3811.5 kN
Deflection60%
15.1 / 25.0 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 356×406×551

UC 356×406×551 has a mass of 551 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 6612 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 356×406×551 has a depth of 455.6 mm, a width of 418.5 mm, a web thickness of 42.1 mm, a flange thickness of 67.5 mm, with a cross-sectional area of 702 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 12,100 cm³, and the elastic modulus Wel,y is 9,960 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 4296 kNm before any stability check.

The second moment of area about the major axis, Iy, is 227,000 cm⁴, and about the minor axis Iz is 82,700 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 2.56 for the flange and cw/tw = 6.89 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 18 cm about the major axis and iz is 10.9 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 10.9 cm a 1.1 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 9,240 cm⁴, and the warping constant Iw is 31.1 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 356×406×634UC 356×406×467UC 356×406×393UC 356×406×340UC 356×406×287UC 356×406×235UC 356×368×202UC 356×368×177

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 14X370

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…