CivilAxisCivilAxis
☕ Support🌐 Community

UC 203×203×100 - Section Properties

The UC 203×203×100 is a universal column with a mass of 99.6 kg/m, an overall depth of 228.6 mm and width of 210.3 mm. It has a cross-sectional area of 127 cm², a second moment of area Iᵧ of 11300 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1150 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
99.6 kg/m
Depth
228.6 mm
Width
210.3 mm
Area
127 cm²
Ask about capacity, buckling or detailing for UC 203×203×100.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UC section profile showing the dimension symbols used for UC 203×203×100

Dimension symbols for UC sections. Not to scale.

UC 203×203×100 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh228.6
Width of sectionb210.3
Web thicknesstw14.5
Flange thicknesstf23.7
Root fillet radiusr10.2
Depth between filletsd160.8

Mass and area

Mass per metremass99.6
Cross-sectional areaA127

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy11300
Elastic section modulus about y-axisWel,y988
Plastic section modulus about y-axisWpl,y1150
Radius of gyration about y-axisiy9.44

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3680
Elastic section modulus about z-axisWel,z350
Plastic section modulus about z-axisWpl,z534
Radius of gyration about z-axisiz5.39

Torsion and warping

Torsion constant (St Venant)It210
Warping constantIw0.386

Classification and stability

Flange local-buckling ratiocf/tf3.7
Web local-buckling ratiocw/tw11.1
Buckling parameteru0.852
Torsional indexX9.02

Detailing dimensions

End clearanceC9
Notch dimension NN108
Notch dimension nn34

Surface area

Surface area per metreSA/m1.25
Surface area per tonneSA/t12.6m²/t

Is UC 203×203×100 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending31%
125.3 / 408.3 kNm
Shear15%
111.4 / 729.4 kN
Deflection59%
7.4 / 12.5 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UC 203×203×100

UC 203×203×100 has a mass of 99.6 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1195 kg, which is the figure to use for a steel take-off or when checking a lift.

UC 203×203×100 has a depth of 228.6 mm, a width of 210.3 mm, a web thickness of 14.5 mm, a flange thickness of 23.7 mm, with a cross-sectional area of 127 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,150 cm³, and the elastic modulus Wel,y is 988 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 408 kNm before any stability check.

The second moment of area about the major axis, Iy, is 11,300 cm⁴, and about the minor axis Iz is 3,680 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 3.7 for the flange and cw/tw = 11.1 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 9.44 cm about the major axis and iz is 5.39 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5.39 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 210 cm⁴, and the warping constant Iw is 0.386 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UC sizes

UC 254×254×89UC 254×254×73UC 203×203×127UC 203×203×113UC 203×203×86UC 203×203×71UC 203×203×60UC 203×203×52

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs HE 200 Mvs W 8X67

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UC sizes
Universal Columns (UC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…