CF CHS 508×16 - Section Properties
The CF CHS 508×16 is a circular hollow section with a mass of 194 kg/m, an overall depth of 508 mm and width of 508 mm and a wall thickness of 16 mm. It has a cross-sectional area of 247 cm², a second moment of area Iᵧ of 74900 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3870 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for CF CHS 508×16.
or pick a unit on any row

Dimension symbols for CHS Cold-formed sections. Not to scale.
Is CF CHS 508×16 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending27%
375.0 / 1373.8 kNmShear6%
150.0 / 2531.2 kNDeflection60%
16.6 / 27.8 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about CF CHS 508×16
Related CHS Cold-formed sizes
Compare with other sections
Side-by-side properties against the closest equivalent in each catalogue.
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.