CivilAxisCivilAxis
☕ Support🌐 Community

PFC 125×65×15 - Section Properties

The PFC 125×65×15 is a parallel flange channel with a mass of 14.8 kg/m, an overall depth of 125 mm and width of 65 mm. It has a cross-sectional area of 18.8 cm², a second moment of area Iᵧ of 483 cm⁴, a plastic modulus Wₚₗ,ᵧ of 89.9 cm³, tabulated by CivilAxis from BS EN 1993-1-1:2005 / BS 4-1:2005 (SCI P363 Blue Book).

Mass
14.8 kg/m
Depth
125 mm
Width
65 mm
Area
18.8 cm²
Ask about capacity, buckling or detailing for PFC 125×65×15.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
PFC section profile showing the dimension symbols used for PFC 125×65×15

Dimension symbols for PFC sections. Not to scale.

PFC 125×65×15 section properties to BS EN 1993-1-1:2005 / BS 4-1:2005.

Geometry

Depth of sectionh125
Width of sectionb65
Web thicknesstw5.5
Flange thicknesstf9.5
Root fillet radiusr12
Depth between filletsd82

Mass and area

Mass per metremass14.8
Cross-sectional areaA18.8

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy483
Elastic section modulus about y-axisWel,y77.3
Plastic section modulus about y-axisWpl,y89.9
Radius of gyration about y-axisiy5.07

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz80
Elastic section modulus about z-axisWel,z18.8
Plastic section modulus about z-axisWpl,z33.2
Radius of gyration about z-axisiz2.06

Torsion and warping

Torsion constant (St Venant)It4.72
Warping constantIw0.00194

Classification and stability

Flange local-buckling ratiocf/tf5
Web local-buckling ratiocw/tw14.9
Buckling parameteru0.942
Torsional indexX11.1

Detailing dimensions

End clearanceC8
Notch dimension NN66
Notch dimension nn22
Distance from web face to flange tipe02.56

Surface area

Surface area per metreSA/m0.489
Surface area per tonneSA/t33.1m²/t

Is PFC 125×65×15 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending31%
10.0 / 31.9 kNm
Shear10%
15.9 / 166.3 kN
Deflection61%
4.3 / 6.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about PFC 125×65×15

PFC 125×65×15 has a mass of 14.8 kg/m, tabulated to BS EN 1993-1-1:2005 / BS 4-1:2005. A 12 m length therefore weighs about 178 kg, which is the figure to use for a steel take-off or when checking a lift.

PFC 125×65×15 has a depth of 125 mm, a width of 65 mm, a web thickness of 5.5 mm, a flange thickness of 9.5 mm, with a cross-sectional area of 18.8 cm². These are the nominal dimensions from BS EN 1993-1-1:2005 / BS 4-1:2005; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 89.9 cm³, and the elastic modulus Wel,y is 77.3 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 32 kNm before any stability check.

The second moment of area about the major axis, Iy, is 483 cm⁴, and about the minor axis Iz is 80 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5 for the flange and cw/tw = 14.9 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 5.07 cm about the major axis and iz is 2.06 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.06 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 4.72 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related PFC sizes

PFC 230×75×26PFC 200×90×30PFC 200×75×23PFC 180×90×26PFC 180×75×20PFC 150×90×24PFC 150×75×18PFC 100×50×10

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs PFC 125×65

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All PFC sizes
Parallel Flange Channels (PFC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…