CivilAxisCivilAxis
☕ Support🌐 Community

PFC 300×100×46 - Section Properties

The PFC 300×100×46 is a parallel flange channel with a mass of 45.5 kg/m, an overall depth of 300 mm and width of 100 mm. It has a cross-sectional area of 58 cm², a second moment of area Iᵧ of 8230 cm⁴, a plastic modulus Wₚₗ,ᵧ of 641 cm³, tabulated by CivilAxis from BS EN 1993-1-1:2005 / BS 4-1:2005 (SCI P363 Blue Book).

Mass
45.5 kg/m
Depth
300 mm
Width
100 mm
Area
58 cm²
Ask about capacity, buckling or detailing for PFC 300×100×46.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
PFC section profile showing the dimension symbols used for PFC 300×100×46

Dimension symbols for PFC sections. Not to scale.

PFC 300×100×46 section properties to BS EN 1993-1-1:2005 / BS 4-1:2005.

Geometry

Depth of sectionh300
Width of sectionb100
Web thicknesstw9
Flange thicknesstf16.5
Root fillet radiusr15
Depth between filletsd237

Mass and area

Mass per metremass45.5
Cross-sectional areaA58

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy8230
Elastic section modulus about y-axisWel,y549
Plastic section modulus about y-axisWpl,y641
Radius of gyration about y-axisiy11.9

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz568
Elastic section modulus about z-axisWel,z81.7
Plastic section modulus about z-axisWpl,z148
Radius of gyration about z-axisiz3.13

Torsion and warping

Torsion constant (St Venant)It36.8
Warping constantIw0.0813

Classification and stability

Flange local-buckling ratiocf/tf4.61
Web local-buckling ratiocw/tw26.3
Buckling parameteru0.944
Torsional indexX17

Detailing dimensions

End clearanceC11
Notch dimension NN98
Notch dimension nn32
Distance from web face to flange tipe03.68

Surface area

Surface area per metreSA/m0.969
Surface area per tonneSA/t21.3m²/t

Is PFC 300×100×46 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending30%
67.5 / 227.6 kNm
Shear8%
45.0 / 593.6 kN
Deflection59%
9.8 / 16.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about PFC 300×100×46

PFC 300×100×46 has a mass of 45.5 kg/m, tabulated to BS EN 1993-1-1:2005 / BS 4-1:2005. A 12 m length therefore weighs about 546 kg, which is the figure to use for a steel take-off or when checking a lift.

PFC 300×100×46 has a depth of 300 mm, a width of 100 mm, a web thickness of 9 mm, a flange thickness of 16.5 mm, with a cross-sectional area of 58 cm². These are the nominal dimensions from BS EN 1993-1-1:2005 / BS 4-1:2005; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 641 cm³, and the elastic modulus Wel,y is 549 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 228 kNm before any stability check.

The second moment of area about the major axis, Iy, is 8,230 cm⁴, and about the minor axis Iz is 568 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.61 for the flange and cw/tw = 26.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 11.9 cm about the major axis and iz is 3.13 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.13 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 36.8 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related PFC sizes

PFC 430×100×64PFC 380×100×54PFC 300×90×41PFC 260×90×35PFC 260×75×28PFC 230×90×32PFC 230×75×26PFC 200×90×30

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs PFC 300×100vs MC 12X31

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All PFC sizes
Parallel Flange Channels (PFC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…