CivilAxisCivilAxis
☕ Support🌐 Community

CF SHS 400×400×10 - Section Properties

The CF SHS 400×400×10 is a square hollow section with a mass of 120 kg/m, an overall depth of 400 mm and width of 400 mm and a wall thickness of 10 mm. It has a cross-sectional area of 153 cm², a second moment of area Iᵧ of 38200 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2210 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
120 kg/m
Depth
400 mm
Width
400 mm
Wall thickness
10 mm
Area
153 cm²
Ask about capacity, buckling or detailing for CF SHS 400×400×10.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Cold-formed section profile showing the dimension symbols used for CF SHS 400×400×10

Dimension symbols for SHS Cold-formed sections. Not to scale.

CF SHS 400×400×10 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh400
Width of sectionb400
Wall thicknesst10

Mass and area

Mass per metremass120
Cross-sectional areaA153

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy38200
Elastic section modulus about y-axisWel,y1910
Plastic section modulus about y-axisWpl,y2210
Radius of gyration about y-axisiy15.8

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz38200
Elastic section modulus about z-axisWel,z1910
Plastic section modulus about z-axisWpl,z2210
Radius of gyration about z-axisiz15.8

Torsion and warping

Torsion constant (St Venant)It60400
Section modulus for torsionWt2890

Surface area

Surface area per metreSA/m1.56
Surface area per tonneSA/t13m²/t

Common questions about CF SHS 400×400×10

CF SHS 400×400×10 has a mass of 120 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 1440 kg, which is the figure to use for a steel take-off or when checking a lift.

CF SHS 400×400×10 has a depth of 400 mm, a width of 400 mm, a wall thickness of 10 mm, with a cross-sectional area of 153 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 2,210 cm³, and the elastic modulus Wel,y is 1,910 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 785 kNm before any stability check.

The second moment of area about the major axis, Iy, is 38,200 cm⁴, and about the minor axis Iz is 38,200 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 15.8 cm about the major axis and iz is 15.8 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 15.8 cm a 1.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 60,400 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Cold-formed sizes

CF SHS 350×350×10CF SHS 350×350×12CF SHS 350×350×12.5CF SHS 400×400×6CF SHS 400×400×6.3CF SHS 400×400×8CF SHS 400×400×12CF SHS 400×400×12.5

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs SHS 400×400×10

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Cold-formed sizes
Square Hollow Sections - Cold-formed (BS EN 10219)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…