Z25019 - Section Properties

The Z25019 is a cold-formed Z-purlin with a mass of 6.5 kg/m, an overall depth of 254 mm and width of 79 mm and a wall thickness of 1.9 mm. It has a cross-sectional area of 8.08 cm², a second moment of area Iᵧ of 7.82 cm⁴, an elastic modulus Wₑₗ,ᵧ of 14 cm³, tabulated by CivilAxis from Continental Steel.

Mass
6.5 kg/m
Depth
254 mm
Width
79 mm
Wall thickness
1.9 mm
Area
8.08 cm²
Ask about capacity, buckling or detailing for Z25019.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
Z25019 section properties to Continental Steel.

Geometry

Depth of sectionh254
Width of sectionb79
Wall thicknesst1.9

Mass and area

Mass per metremass6.5
Cross-sectional areaA8.08

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy7.82
Elastic section modulus about y-axisWel,y14
Radius of gyration about y-axisiy83.3

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz21.7
Elastic section modulus about z-axisWel,z762
Radius of gyration about z-axisiz181

Principal axes

Area moment of inertia about u-u (major principal) axisIu808
Area moment of inertia about v-v (minor principal) axisIv3.81

Common questions about Z25019

Z25019 has a mass of 6.5 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 78 kg, which is the figure to use for a steel take-off or when checking a lift.

Z25019 has a depth of 254 mm, a width of 79 mm, a wall thickness of 1.9 mm, with a cross-sectional area of 8.08 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The elastic section modulus about the major axis, Wel,y, is 14 cm³. Use it with M_el,Rd = Wel,y x f_y / gamma_M0 for an elastic check.

The second moment of area about the major axis, Iy, is 7.82 cm⁴, and about the minor axis Iz is 21.7 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 83.3 cm about the major axis and iz is 181 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 181 cm a 18.1 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related Z-Purlin sizes

Z15024Z20015Z20019Z20024Z25024Z30024Z30030Z35030

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All Z-Purlin sizes
Z-Purlins (cold-formed)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…