CivilAxisCivilAxis
☕ Support🌐 Community

Z30024 - Section Properties

The Z30024 is a cold-formed Z-purlin with a mass of 10.09 kg/m, an overall depth of 300 mm and width of 100 mm and a wall thickness of 2.4 mm. It has a cross-sectional area of 12.6 cm², a second moment of area Iᵧ of 16.8 cm⁴, an elastic modulus Wₑₗ,ᵧ of 16 cm³, tabulated by CivilAxis from Continental Steel.

Mass
10.09 kg/m
Depth
300 mm
Width
100 mm
Wall thickness
2.4 mm
Area
12.6 cm²
Ask about capacity, buckling or detailing for Z30024.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
Z30024 section properties to Continental Steel.

Geometry

Depth of sectionh300
Width of sectionb100
Wall thicknesst2.4

Mass and area

Mass per metremass10.09
Cross-sectional areaA12.6

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy16.8
Elastic section modulus about y-axisWel,y16
Radius of gyration about y-axisiy232

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz28.3
Elastic section modulus about z-axisWel,z1700
Radius of gyration about z-axisiz457

Principal axes

Area moment of inertia about u-u (major principal) axisIu1830
Area moment of inertia about v-v (minor principal) axisIv1.01

Common questions about Z30024

Z30024 has a mass of 10.09 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 121 kg, which is the figure to use for a steel take-off or when checking a lift.

Z30024 has a depth of 300 mm, a width of 100 mm, a wall thickness of 2.4 mm, with a cross-sectional area of 12.6 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The elastic section modulus about the major axis, Wel,y, is 16 cm³. Use it with M_el,Rd = Wel,y x f_y / gamma_M0 for an elastic check.

The second moment of area about the major axis, Iy, is 16.8 cm⁴, and about the minor axis Iz is 28.3 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 232 cm about the major axis and iz is 457 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 457 cm a 45.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related Z-Purlin sizes

Z15024Z20015Z20019Z20024Z25019Z25024Z30030Z35030

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)