CivilAxisCivilAxis
☕ Support🌐 Community

2×PFC 100×50×10 Laced - Section Properties

The 2×PFC 100×50×10 Laced is a parallel flange channel with a mass of 20.4 kg/m. It has a cross-sectional area of 26 cm², a second moment of area Iᵧ of 415 cm⁴, a plastic modulus Wₚₗ,ᵧ of 97.7 cm³, tabulated by CivilAxis from BS EN 1993-1-1:2005 / BS 4-1:2005 (SCI P363 Blue Book).

Mass
20.4 kg/m
Area
26 cm²
Ask about capacity, buckling or detailing for 2×PFC 100×50×10 Laced.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
PFC Laced section profile showing the dimension symbols used for 2×PFC 100×50×10 Laced

Dimension symbols for PFC Laced sections. Not to scale.

2×PFC 100×50×10 Laced section properties to BS EN 1993-1-1:2005 / BS 4-1:2005.

Mass and area

Mass per metremass20.4
Cross-sectional areaA26

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy415
Elastic section modulus about y-axisWel,y83.1
Plastic section modulus about y-axisWpl,y97.7
Radius of gyration about y-axisiy4

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz427
Elastic section modulus about z-axisWel,z61
Plastic section modulus about z-axisWpl,z97.1
Radius of gyration about z-axisiz4.05

Common questions about 2×PFC 100×50×10 Laced

2×PFC 100×50×10 Laced has a mass of 20.4 kg/m, tabulated to BS EN 1993-1-1:2005 / BS 4-1:2005. A 12 m length therefore weighs about 245 kg, which is the figure to use for a steel take-off or when checking a lift.

The plastic section modulus about the major axis, Wpl,y, is 97.7 cm³, and the elastic modulus Wel,y is 83.1 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 35 kNm before any stability check.

The second moment of area about the major axis, Iy, is 415 cm⁴, and about the minor axis Iz is 427 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 4 cm about the major axis and iz is 4.05 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.05 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related PFC Laced sizes

2×PFC 230×75×26 Laced2×PFC 200×90×30 Laced2×PFC 200×75×23 Laced2×PFC 180×90×26 Laced2×PFC 180×75×20 Laced2×PFC 150×90×24 Laced2×PFC 150×75×18 Laced2×PFC 125×65×15 Laced

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)