2×PFC 150×90×24 Laced - Section Properties

The 2×PFC 150×90×24 Laced is a parallel flange channel with a mass of 47.7 kg/m. It has a cross-sectional area of 60.8 cm², a second moment of area Iᵧ of 2320 cm⁴, a plastic modulus Wₚₗ,ᵧ of 632 cm³, tabulated by CivilAxis from BS EN 1993-1-1:2005 / BS 4-1:2005 (SCI P363 Blue Book).

Mass
47.7 kg/m
Area
60.8 cm²
Ask about capacity, buckling or detailing for 2×PFC 150×90×24 Laced.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
PFC Laced section profile showing the dimension symbols used for 2×PFC 150×90×24 Laced

Dimension symbols for PFC Laced sections. Not to scale.

2×PFC 150×90×24 Laced section properties to BS EN 1993-1-1:2005 / BS 4-1:2005.

Mass and area

Mass per metremass47.7
Cross-sectional areaA60.8

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2320
Elastic section modulus about y-axisWel,y310
Plastic section modulus about y-axisWpl,y632
Radius of gyration about y-axisiy6.18

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2380
Elastic section modulus about z-axisWel,z212
Plastic section modulus about z-axisWpl,z338
Radius of gyration about z-axisiz6.26

Common questions about 2×PFC 150×90×24 Laced

2×PFC 150×90×24 Laced has a mass of 47.7 kg/m, tabulated to BS EN 1993-1-1:2005 / BS 4-1:2005. A 12 m length therefore weighs about 572 kg, which is the figure to use for a steel take-off or when checking a lift.

The plastic section modulus about the major axis, Wpl,y, is 632 cm³, and the elastic modulus Wel,y is 310 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 224 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,320 cm⁴, and about the minor axis Iz is 2,380 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 6.18 cm about the major axis and iz is 6.26 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.26 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related PFC Laced sizes

2×PFC 230×75×26 Laced2×PFC 200×90×30 Laced2×PFC 200×75×23 Laced2×PFC 180×90×26 Laced2×PFC 180×75×20 Laced2×PFC 150×75×18 Laced2×PFC 125×65×15 Laced2×PFC 100×50×10 Laced

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)