CivilAxisCivilAxis
☕ Support🌐 Community

2×PFC 150×75×18 Laced - Section Properties

The 2×PFC 150×75×18 Laced is a parallel flange channel with a mass of 35.7 kg/m. It has a cross-sectional area of 45.5 cm², a second moment of area Iᵧ of 1720 cm⁴, a plastic modulus Wₚₗ,ᵧ of 264 cm³, tabulated by CivilAxis from BS EN 1993-1-1:2005 / BS 4-1:2005 (SCI P363 Blue Book).

Mass
35.7 kg/m
Area
45.5 cm²
Ask about capacity, buckling or detailing for 2×PFC 150×75×18 Laced.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
PFC Laced section profile showing the dimension symbols used for 2×PFC 150×75×18 Laced

Dimension symbols for PFC Laced sections. Not to scale.

2×PFC 150×75×18 Laced section properties to BS EN 1993-1-1:2005 / BS 4-1:2005.

Mass and area

Mass per metremass35.7
Cross-sectional areaA45.5

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy1720
Elastic section modulus about y-axisWel,y230
Plastic section modulus about y-axisWpl,y264
Radius of gyration about y-axisiy6.15

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1810
Elastic section modulus about z-axisWel,z168
Plastic section modulus about z-axisWpl,z265
Radius of gyration about z-axisiz6.3

Common questions about 2×PFC 150×75×18 Laced

2×PFC 150×75×18 Laced has a mass of 35.7 kg/m, tabulated to BS EN 1993-1-1:2005 / BS 4-1:2005. A 12 m length therefore weighs about 428 kg, which is the figure to use for a steel take-off or when checking a lift.

The plastic section modulus about the major axis, Wpl,y, is 264 cm³, and the elastic modulus Wel,y is 230 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 94 kNm before any stability check.

The second moment of area about the major axis, Iy, is 1,720 cm⁴, and about the minor axis Iz is 1,810 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 6.15 cm about the major axis and iz is 6.3 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.3 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related PFC Laced sizes

2×PFC 230×75×26 Laced2×PFC 200×90×30 Laced2×PFC 200×75×23 Laced2×PFC 180×90×26 Laced2×PFC 180×75×20 Laced2×PFC 150×90×24 Laced2×PFC 125×65×15 Laced2×PFC 100×50×10 Laced

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All PFC Laced sizes
Two PFC - Laced
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…