CivilAxisCivilAxis
☕ Support🌐 Community

2×PFC 125×65×15 Laced - Section Properties

The 2×PFC 125×65×15 Laced is a parallel flange channel with a mass of 29.5 kg/m. It has a cross-sectional area of 37.6 cm², a second moment of area Iᵧ of 966 cm⁴, a plastic modulus Wₚₗ,ᵧ of 178 cm³, tabulated by CivilAxis from BS EN 1993-1-1:2005 / BS 4-1:2005 (SCI P363 Blue Book).

Mass
29.5 kg/m
Area
37.6 cm²
Ask about capacity, buckling or detailing for 2×PFC 125×65×15 Laced.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
PFC Laced section profile showing the dimension symbols used for 2×PFC 125×65×15 Laced

Dimension symbols for PFC Laced sections. Not to scale.

2×PFC 125×65×15 Laced section properties to BS EN 1993-1-1:2005 / BS 4-1:2005.

Mass and area

Mass per metremass29.5
Cross-sectional areaA37.6

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy966
Elastic section modulus about y-axisWel,y155
Plastic section modulus about y-axisWpl,y178
Radius of gyration about y-axisiy5.07

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1010
Elastic section modulus about z-axisWel,z107
Plastic section modulus about z-axisWpl,z178
Radius of gyration about z-axisiz5.18

Common questions about 2×PFC 125×65×15 Laced

2×PFC 125×65×15 Laced has a mass of 29.5 kg/m, tabulated to BS EN 1993-1-1:2005 / BS 4-1:2005. A 12 m length therefore weighs about 354 kg, which is the figure to use for a steel take-off or when checking a lift.

The plastic section modulus about the major axis, Wpl,y, is 178 cm³, and the elastic modulus Wel,y is 155 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 63 kNm before any stability check.

The second moment of area about the major axis, Iy, is 966 cm⁴, and about the minor axis Iz is 1,010 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 5.07 cm about the major axis and iz is 5.18 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5.18 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related PFC Laced sizes

2×PFC 230×75×26 Laced2×PFC 200×90×30 Laced2×PFC 200×75×23 Laced2×PFC 180×90×26 Laced2×PFC 180×75×20 Laced2×PFC 150×90×24 Laced2×PFC 150×75×18 Laced2×PFC 100×50×10 Laced

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)