CivilAxisCivilAxis
☕ Support🌐 Community

AISC C-Shapes (American Standard Channel) - Section Properties

Section DesignationMass per MetreDimensionsSecond Moment of AreaRadius of GyrationElastic ModulusPlastic ModulusWarping ConstantTorsional ConstantArea of Section
massi
hi
bi
twi
tfi
Iyi
Izi
iyi
izi
Wel,yi
Wel,zi
Wpl,yi
Wpl,zi
Iwi
Iti
Ai
lb/ftininininin⁴in⁴ininin³in³in³in³in⁶in⁴in²
C15X5050.015.03.70.70.714.7404.053.8068.505.2411.003.7708.1400.872.650492.0
C15X4040.015.03.50.50.711.8348.046.5057.505.439.1703.3406.8400.881.450410.0
C15X33.933.915.03.40.40.710.0315.042.0050.805.618.0703.0906.1900.901.010358.0
C12X3030.012.03.20.50.58.8162.027.0033.804.295.1202.0504.3200.760.861151.0
C12X2525.012.03.10.40.57.3144.024.0029.404.434.4501.8703.8200.780.538130.0
C12X20.720.712.02.90.30.56.1129.021.5025.604.613.8601.7203.4700.800.369112.0
C10X3030.010.03.00.70.48.8103.020.7026.703.433.9301.6503.7800.671.22079.50
C10X2525.010.02.90.50.47.491.1018.2023.103.523.3401.4703.1800.680.68768.30
C10X2020.010.02.70.40.45.978.9015.8019.403.672.8001.3102.7000.690.36856.90
C10X15.315.310.02.60.20.44.567.3013.5015.903.882.2701.1502.3400.710.20945.50
C9X2020.09.02.70.40.45.960.9013.5016.903.222.4101.1702.4600.640.42739.40
C9X1515.09.02.50.30.44.451.0011.3013.603.401.9101.0102.0400.660.20831.00
C9X13.413.49.02.40.20.43.947.8010.6012.603.481.7500.9541.9400.670.16828.20
C8X18.7518.88.02.50.50.45.543.9011.0013.902.821.9701.0102.1700.600.43425.10
C8X13.7513.88.02.30.30.44.036.109.02011.002.991.5200.8481.7300.610.18619.20
C8X11.511.58.02.30.20.43.432.508.1409.6303.111.3100.7751.5700.620.13016.50
C7X14.7514.87.02.30.40.44.327.207.7809.7502.511.3700.7721.6300.560.26713.10
C7X12.2512.37.02.20.30.43.624.206.9208.4602.591.1600.6961.4200.570.16111.20
C7X9.89.87.02.10.20.42.921.206.0707.1902.720.9570.6171.2600.580.1009.150
C6X1313.06.02.20.40.33.817.305.7807.2902.131.0500.6381.3500.520.2377.190
C6X10.510.56.02.00.30.33.115.105.0406.1802.220.8600.5611.1400.530.1285.910
C6X8.28.26.01.90.20.32.413.104.3505.1602.340.6870.4880.9870.540.0744.700
C5X99.05.01.90.30.32.68.8903.5604.3901.840.6240.4440.9130.490.1092.930
C5X6.76.75.01.80.20.32.07.4802.9903.5501.950.4700.3720.7570.490.0552.220
C4X7.257.34.01.70.30.32.14.5802.2902.8401.470.4250.3370.6950.450.0821.240
C4X6.256.34.01.70.20.31.84.1902.1002.5501.510.3740.3120.6230.450.0551.070
C4X5.45.44.01.60.20.31.63.8501.9202.2901.560.3120.2770.5650.440.0400.921
C4X4.54.54.01.50.10.31.33.5301.7702.0501.620.2650.2530.4950.450.0310.778
C3X66.03.01.60.40.31.82.0701.3801.7401.090.3000.2630.5430.410.0730.462
C3X55.03.01.50.30.31.51.8501.2301.5201.120.2410.2280.4640.410.0430.379
C3X4.14.13.01.40.20.31.21.6501.1001.3201.180.1910.1960.3990.400.0270.307
C3X3.53.53.01.40.10.31.11.5701.0401.2401.200.1690.1820.3640.390.0230.276

Section dimensions and properties for AISC C-Shapes (American Standard Channel).

Related section types

Learn more

AISC C-Shapes (American Standard Channel) - section properties reference

What is in the C table

This page lists every AISC C-Shapes (American Standard Channel) size to AISC Shapes Database v16.0, with the full set of section properties for each one. The table is sortable on any column and searchable by designation, and each size links to its own page with the complete property set, a worked capacity check and dimensions for detailing.

Sizes in this table
32
Mass range (lb/ft)
3.5 to 50.0 - from C3X3.5 up to C15X50
Depth range (in)
3.0 to 15.0
Major-axis stiffness, I (in⁴)
1.57 to 404 - a factor of 257 across the range
Published to
AISC Shapes Database v16.0

The spread is worth noticing: the heaviest C weighs 14.3x the lightest but carries roughly 257x the major-axis stiffness. Bending stiffness grows far faster than weight, which is the whole reason the range is shaped this way - going deeper buys stiffness much more cheaply than going heavier.

How to read a C-shape designation

An AISC designation is the shape letter, the nominal depth in inches, then the weight in pounds per foot: C7X14.75. The first number is a NOMINAL depth, not the measured one - shapes rolled from the same family share a nominal depth while their real depth varies with flange thickness, which is why the depth column in the table above rarely matches the name exactly.

The second number is the only part that is exact: it is the weight per foot, and it is what distinguishes two shapes of the same nominal depth.

What each column in the table means

The table above publishes 16 properties for every C size. These are the ones that decide a design:

Mass per metre
Self-weight of the section, and the basis on which steel is bought - so it is the first cost signal when comparing two sections that both pass.
Cross-sectional area, A
Governs axial capacity and, with mass, tells you how efficiently the shape uses its steel.
Second moment of area, I (major axis)
Resistance to bending about the strong axis. It is what deflection is proportional to, so a serviceability check is driven by this number rather than by strength.
Second moment of area about the minor axis
The weak-axis stiffness. It sets lateral-torsional buckling behaviour and matters whenever the compression flange is not continuously restrained.
Elastic section modulus, Wel
Moment capacity while the extreme fibre stays elastic - the value to use for a Class 3 section, and for any check where yielding is not permitted.
Plastic section modulus, Wpl
Moment capacity once the whole section has yielded - the value used for Class 1 and 2 sections, and typically 10-20% above the elastic modulus.
Radius of gyration, i
The slenderness term: effective length divided by i gives the slenderness that drives buckling. The minor-axis value normally governs a column.
Torsion constant, J
St Venant torsional stiffness. Closed shapes carry torsion through a shear flow around the perimeter and have a J orders of magnitude above an open shape of the same weight.
Warping constant, Cw
The second half of torsional resistance in an open section, and an input to lateral-torsional buckling. It is what makes an I-section usable in torsion at all.

Every one of these is a property of the shape alone. None of them depends on the steel grade - grade enters only when a property is multiplied by a design strength to give a capacity, which is what the Capacity tab above does.

Choosing a C size

Which property governs depends on what is being checked, and it is rarely the one people reach for first:

Bending strength
Compare plastic modulus Wpl for Class 1 and 2 sections, elastic Wel for Class 3. Depth buys this cheaply.
Deflection
Compare second moment of area I. A section that passes strength can still fail serviceability, and this is usually the check that decides the size.
Compression
Compare the MINOR-axis radius of gyration. A deep section with a narrow flange is efficient in bending and poor as a column.
Torsion
Compare J. If the load is genuinely torsional, a closed section beats an open one so decisively that the comparison is rarely close.
Cost
Compare mass per metre first, then surface area per metre - protective treatment is charged by area, not weight.
Elastic section modulus
Wel=IcW_{el} = \frac{I}{c}
Radius of gyration
i=IAi = \sqrt{\frac{I}{A}}
Slenderness
λ=Lcri\lambda = \frac{L_{cr}}{i}

Open the Capacity tab above with a size selected to run these as a full EC3 check rather than comparing the raw properties by eye.

Common questions about C sections

32 AISC C-Shapes (American Standard Channel) sizes are published to AISC Shapes Database v16.0, and all 32 are listed in the table above. Availability from stock is a separate question from what the standard publishes - check with a supplier before specifying an unusual size.

The lightest is C3X3.5 at 3.5 lb/ft, and the heaviest is C15X50 at 50.0 lb/ft.

No. Everything in the table above is geometry - area, second moment of area, section moduli, radii of gyration and torsion constants are properties of the shape and are identical in S235, S275 and S355. Grade only enters when a property is multiplied by a design strength to produce a capacity.

Both. The table renders imperial-primary because that is how AISC publishes them, and every size page gives the same values in millimetres, kilograms and metric property units alongside the inch-pound set.

Yes. Select a size and open the Capacity tab above to run an EC3 check - bending, shear, compression and the combined interaction - or open that size's own page for a worked example with the numbers substituted.

Rate this
No ratings yet
Sign in to join the discussion.
Loading…