Crack Width to EC2: Calculating wk Step by Step
Eurocode 2 limits crack width to 0.3 mm for most reinforced concrete, but the calculation behind that number is rarely shown in full. This article works through §7.3.4 from the cracked section analysis to the final wk: how the maximum crack spacing is built from cover and bar diameter, why the effective tension area is not the whole section, what the 0.6 floor on the strain difference is protecting, and a complete 300 by 600 beam check with every intermediate value.

A crack in reinforced concrete is not a defect. Reinforced concrete works by cracking: the concrete lets go of the tension, the steel picks it up, and the member carries on. What the code controls is not whether the section cracks but how wide the cracks open, because width is what governs durability, water-tightness and whether the owner thinks the structure is broken.
What the check does
EN 1992-1-1 §7.3.1 asks that the calculated crack width stays under a limit that depends on the exposure class and on whether the member is prestressed:
Table 7.1N recommends for reinforced members in exposure classes XC2 to XS3, checked under the quasi-permanent combination. For X0 and XC1 the recommendation relaxes to 0.4 mm, since the concern there is appearance rather than durability. Prestressed members with bonded tendons are tighter: 0.2 mm, and under the frequent combination.
Three things are worth saying before any arithmetic. The limit is a durability and appearance limit, not a strength limit - a member with a 0.35 mm crack is no weaker. The calculated is a characteristic value with real scatter around it, so treating 0.31 against 0.30 as a hard pass or fail is reading more precision into the model than it has. And §7.3.3 offers a simplified route: satisfy the bar diameter or bar spacing limits of Table 7.3N and no calculation is needed at all.
The governing formula
where:
- characteristic crack width (mm)
- maximum crack spacing (mm)
- mean strain in the reinforcement under the relevant combination, including the effect of imposed deformations and tension stiffening
- mean strain in the concrete between cracks
The shape of it is simply geometry: a crack opens by the amount the steel stretches more than the concrete does, over the length of concrete that belongs to that crack. Everything else in §7.3.4 is working out those two quantities.
Step 1 - the cracked section
Before anything in §7.3.4 can be evaluated, you need the steel stress under the quasi-permanent combination. That comes from a cracked transformed section analysis: assume the concrete carries no tension, find the neutral axis depth where the compressive and tensile first moments balance, then take the second moment of area of what is left.
where:
- neutral axis depth measured from the compression face (mm)
- modular ratio
, - tension and compression steel areas ()
, - effective depths to the tension and compression steel (mm)
- second moment of area of the cracked transformed section ()
The steel stress then follows from ordinary elastic bending:
One decision hides in . For a short-term check, is the tabulated secant modulus. For the quasi-permanent combination, which is a long-term state, an effective modulus is more honest, and the creep coefficient can easily be 2. That raises from about 6 to about 18, pushes the neutral axis down, and increases the crack width. The example below uses the short-term modulus so that each step can be followed; a real design should decide this question explicitly rather than inherit it from a default.
Step 2 - maximum crack spacing
where:
- clear cover to the longitudinal reinforcement (mm)
- bar diameter, or an equivalent diameter for a mixed bundle (mm)
- bond coefficient: 0.8 for high bond bars, 1.6 for bars with an effectively plain surface
- strain distribution coefficient: 0.5 for bending, 1.0 for pure tension
- recommended value 3.4
- recommended value 0.425
- the reinforcement ratio in the effective tension area
The two terms say different things. is the distance the bond has to travel before it can start transferring force at all, so deeper cover means wider cracks - which is the uncomfortable trade-off at the heart of durability design. The second term is the bond transfer length: more steel in the tension zone, or smaller bars at the same area, means shorter transfer and closer, finer cracks.
is the concrete around the bars that actually participates, not the whole tension zone. Its depth is
For a beam of ordinary proportions the first term usually wins, which makes a small band around the bars. That is deliberate: the tension stiffening effect is local to the bars.
Where the bar spacing exceeds , the bars are too far apart for that model and the code falls back to an upper bound .
Step 3 - the strain difference
where:
- steel stress at the crack, from the cracked section (MPa)
- 0.6 for short-term loading, 0.4 for long-term
- concrete tensile strength at the time cracking is expected, normally (MPa)
- 200 000 MPa
The subtracted term is tension stiffening: between cracks the concrete is still gripping the bar, so the steel's average strain is lower than its strain at the crack face. for long-term loading because sustained load and creep gradually break that grip down.
The floor is the part that is easy to miss. At low steel stress the tension stiffening term can swallow the whole numerator and hand back a negative, physically meaningless strain difference. The floor stops that, and it means a lightly stressed member never reports a crack width of zero.
Minimum reinforcement is the other half of §7.3
§7.3.2 is not optional and it is not the same check:
where:
- area of concrete in the tension zone just before the first crack ()
- stress distribution coefficient: 0.4 for bending, 1.0 for pure tension
- allowance for self-equilibrating stresses: 1.0 for webs up to 300 mm, 0.65 for webs 800 mm or more, interpolated between
- steel stress allowed at the crack, often taken as
The logic is that the steel must be able to carry the force the concrete released at the moment it cracked. If it cannot, the first crack does not stabilise into a pattern of fine cracks - it keeps opening. A section can pass the calculation and still fail this, because the two checks ask different questions.
Worked example
Section: 300 mm wide, 600 mm deep, C30/37, B500. Tension steel 3 bars of 20 mm, centres 40 mm from the soffit. Compression steel 2 bars of 12 mm, centres 40 mm from the top. Clear cover to the main bars . Quasi-permanent moment , no axial force. Limit .
Materials.
Cracked section. With and :
The concrete stress is worth a glance on its own: §7.2 recommends keeping below under the quasi-permanent combination if linear creep is to be assumed, and 14.6 MPa is just over it. In a real design that is a prompt to use non-linear creep or to revisit the section, not a failure.
Effective tension area.
Crack spacing. High bond bars in bending, so and :
Strain difference. Long-term, so :
The floor is , which is lower, so the calculated value governs.
Crack width.
Result: , so the section passes, with about 8% in hand. The margin is thin enough that the creep assumption matters: repeat the check with an effective modulus and the steel stress rises, and so does .
It is also worth noticing what the simplified route would have said. At and , Table 7.3N allows a maximum bar diameter of roughly 9 mm or a maximum spacing of roughly 166 mm. The provided bars are 20 mm at about 100 mm spacing, so the spacing limit is satisfied and the diameter limit is not. Either one is sufficient under §7.3.3, and in any case the direct calculation of §7.3.4 supersedes both.
Key points
: crack opening is the extra steel stretch over the length of concrete belonging to one crack.
Deeper cover gives wider cracks through the term. Durability and crack control pull in opposite directions and the code lets both apply.
Smaller bars at the same steel area give finer cracks, because falls.
is a shallow band around the bars, not the whole tension zone.
The floor stops tension stiffening from returning a negative strain difference at low stress.
Decide the modular ratio deliberately. Using the short-term under a quasi-permanent combination is optimistic.
§7.3.2 minimum reinforcement is a separate check with its own failure mode, and passing does not cover it.
References
- EN 1992-1-1:2004 - Design of concrete structures - Part 1-1 - §7.3.1 Crack control, general considerations
- EN 1992-1-1:2004 - §7.3.2 Minimum reinforcement areas
- EN 1992-1-1:2004 - §7.3.3 Control of cracking without direct calculation, Table 7.3N
- EN 1992-1-1:2004 - §7.3.4 Calculation of crack widths