Torsion in RC Beams to EC2: the Space Truss Model
Eurocode 2 treats a solid rectangular beam in torsion as a thin-walled tube, which is why the first number you calculate is a wall thickness that does not appear anywhere on the drawing. This article explains where that equivalent tube comes from, when torsion can be ignored altogether, how the crushing interaction with shear works, and takes a 300 by 600 beam under 40 kN.m of torsion through the full check including the closed links and the longitudinal steel.

Torsion is the check most often skipped, and usually that is the right call. Eurocode 2 says so explicitly. But when it does govern - a spandrel beam carrying a slab on one side, a curved beam, a beam supporting a cantilever balcony - it governs hard, and the reinforcement it asks for is not the reinforcement a shear check would have produced.
Equilibrium torsion and compatibility torsion
EN 1992-1-1 §6.3.1(2) splits the problem in two, and the split decides how much work follows.
Equilibrium torsion is torsion the structure cannot shed. If the only path for the load to reach a support is by twisting a member, that twist is required by statics and must be designed for. A cantilever slab framing into a spandrel beam is the classic case: nothing else can carry the slab moment.
Compatibility torsion arises only because members are connected and one of them resists the rotation of another. Here the code allows the torsional stiffness to be ignored at the ultimate limit state, because the member can crack, lose most of its torsional stiffness, and let the moment redistribute. What is still required is minimum reinforcement - closed links and distributed longitudinal bars - so that the cracking is controlled rather than sudden.
Getting this classification wrong in either direction is expensive: design every spandrel for full elastic torsion and you will double its steel; ignore a genuine equilibrium torsion and the member has no mechanism at all.
The equivalent thin-walled tube
The model in §6.3.2 is Bredt's thin-walled tube. A solid section in torsion carries almost all of the shear flow near its outer surface, so the code replaces the solid rectangle with a hollow tube of the same outline. The constant shear flow around that tube is what the reinforcement has to resist.
where:
- effective wall thickness of the equivalent tube (mm)
- total area enclosed by the outer perimeter, including any inner hollow areas ()
- outer perimeter of the section (mm)
- distance from the outer face to the centre of the longitudinal reinforcement (mm)
The floor matters: the wall cannot be thinner than the cage that reinforces it.
From the wall, two further geometric quantities follow, both referred to the centre-line of that wall:
where:
- area enclosed by the centre-line of the wall ()
- perimeter of that centre-line (mm)
The torsional shear stress in the wall is then
which is the whole physical content of the method: a torque becomes a circulating shear flow, and the magnitude of that flow depends only on the torque and on the area the tube encloses.
When torsion reinforcement is not needed
where:
- cracking torque of the section ()
- design tensile strength of concrete (MPa)
If and the shear is similarly low, only minimum reinforcement is required. Above it, the section is designed as a truss. Note that is the torque at cracking, not a reserve capacity: once it is exceeded the concrete contribution does not add to the steel, it is replaced by it.
The crushing limit and its interaction with shear
Torsion and shear both put diagonal compression into the same web, so the crushing check is combined and linear:
where:
- strength reduction factor for concrete cracked in shear
- 1.0 for non-prestressed members
- design compressive strength of concrete (MPa)
- angle of the compression strut, the same angle used in the shear check
This interaction is a real constraint and it is where slender webs fail. peaks at 45 degrees, so a flat strut chosen to save shear links actively reduces the torsional crushing capacity. Shear and torsion must be checked at one consistent , not optimised separately.
Reinforcement for torsion
Two families of steel are needed, and they are not interchangeable.
Closed links, from the shear flow crossing one wall:
Taking in this one formula is a common and deliberately conservative simplification: it returns the largest link area the expression can ask for, and it keeps the link quantity independent of an angle that was chosen to suit the shear check. The worked example below does exactly that, and then shows what carrying the shear angle through would have saved.
The area is per leg of the outer closed link, which is the detail most often got wrong: for a two-leg link the torsion demand applies to each outer leg, and the shear demand applies to the legs together. The two are added:
Longitudinal steel, distributed around the perimeter:
The longitudinal bars are what close the space truss. A tube in torsion needs a diagonal tension field in every wall, and that diagonal resolves into a hoop component (the links) and an axial component (the longitudinal bars). Leaving the longitudinal steel out leaves the truss with no bottom chord.
§9.2.3 adds detailing rules that often govern on small sections: links must be closed with full anchorage, spacing must not exceed , nor , nor the lesser side of the section, and longitudinal bars must be placed at every corner with the rest distributed around at no more than 350 mm apart.
Worked example
Section: 300 mm wide, 600 mm deep, C30/37, B500. Cover to the bar centres 40 mm. Links 2 legs of 10 mm at 150 mm. Longitudinal tension steel 3 bars of 20 mm, .
Actions: , (equilibrium torsion, so it must be designed for).
Design strengths: , , , .
Equivalent tube.
Cracking torque.
, so the section will crack in torsion and full torsion reinforcement is required. Note how narrow that was: 4% more torque than the cracking value turns a minimum-steel case into a designed one.
Strut angle. The shear check with the provided links gives , so , .
Crushing.
The web is comfortably clear of crushing.
Links for torsion, per leg.
Carrying the shear angle through instead, with , would drop this to . That is legitimate, but only if the same angle is used consistently for shear, for the torsion links and for the longitudinal steel.
Links for shear, both legs together. The shear check requires .
Combined link demand.
The provided 2 legs of 10 mm at 150 mm give , which is not enough. Moving to 2 legs of 12 mm at 150 mm gives , which is. Spacing of 150 mm also satisfies §9.2.3: , and are all larger.
Longitudinal steel for torsion.
Distributed around the 1400 mm centre-line perimeter, 6 bars of 16 mm () with one at each corner satisfies this and keeps the spacing under 350 mm. This steel is in addition to the flexural reinforcement in the tension face, although the code permits the longitudinal torsion steel in the compression zone to be reduced where the compressive stress allows.
Result: crushing passes at 62% utilisation, but the originally assumed links are 31% short once torsion and shear are added. The section works with 12 mm closed links at 150 mm plus 6 bars of 16 mm distributed around the perimeter. The lesson of the example is that the crushing interaction passing says nothing about whether the reinforcement is sufficient - they are two separate gates.
Key points
Classify first. Compatibility torsion can be ignored at ULS with minimum reinforcement; equilibrium torsion cannot be ignored at all.
The solid rectangle is replaced by a tube of thickness , and every subsequent quantity refers to that tube's centre-line.
is a cracking torque, not a reserve. Once exceeded, steel replaces the concrete contribution rather than adding to it.
Shear and torsion share the web, so the crushing check is a linear interaction at one common strut angle. A flat strut helps shear links and hurts torsional crushing.
Torsion link area is per leg; shear link area is for all legs. Add them correctly or the links come out roughly half what they should be. Taking for the links is conservative and keeps them independent of the shear angle.
The longitudinal bars are structural, not detailing. Without them the space truss has no chord.
Detailing rules in §9.2.3 frequently govern the link spacing on small sections.
References
- EN 1992-1-1:2004 - Design of concrete structures - Part 1-1 - §6.3.1 Torsion, general
- EN 1992-1-1:2004 - §6.3.2 Design procedure for torsion
- EN 1992-1-1:2004 - §6.2.3 Members requiring design shear reinforcement
- EN 1992-1-1:2004 - §9.2.3 Torsion reinforcement, detailing